DTC P2740 Transmission Fluid Temperature Sensor "B" Circuit |
DTC P2742 Transmission Fluid Temperature Sensor "B" Circuit Low Input |
DTC P2743 Transmission Fluid Temperature Sensor "B" Circuit High Input |

| DTC No. | DTC Detecting Conditions | Trouble Areas |
| P2740 | Conditions (a) and (b) are detected momentarily within 0.5 seconds when neither P2742 nor P2743 is detected. (1-trip detection logic) (a) No. 1 ATF temperature sensor voltage is less than 0.142 V. (b) No. 1 ATF temperature sensor voltage is more than 4.915 V.
|
|
| P2742 | No. 1 ATF temperature sensor voltage is less than 0.142 V for 0.5 seconds or more. (1-trip detection logic) |
|
| P2743 | No. 1 ATF temperature sensor voltage is more than 4.915 V for 0.5 seconds or more 15 minutes or more after starting engine. (1-trip detection logic) |
|
| Related DTCs | P2740: ATF temperature sensor/Range check (Fluttering) P2742: ATF temperature sensor/Range check (Low voltage) P2743: ATF temperature sensor/Range check (High voltage) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| Time after engine start | 15 minutes or more |
| TFT Sensor voltage | Less than 0.142 V or More than 4.915 V |
| TFT Sensor voltage | Less than 0.142 V |
| TFT Sensor voltage | More than 4.915 V |
| ATF temperature sensor | Atmospheric temperature - approximately 130°C (266°F) |

| Item | Measurement Item/ Range (display) | Normal Condition |
| A/T OIL TEMP1 | ATF Temperature Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance.
| Tester Connection | Specified Condition |
| 1 (OT2+) - 5 (OT2-) | 79 Ω to 156 kΩ |
| 1 (OT2+) - Body ground | 10 kΩ or higher |
| 5 (OT2-) - Body ground | 10 kΩ or higher |
| ATF Temperature: | Resistance: |
| 20 °C (68°F) | 3 to 4 kΩ |
| 110 °C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connectors.
Measure the resistance.
| Tester Connection | Specified Condition |
| E5-24 (THO1) - E4-28 (E2) | 79 Ω to 156 kΩ |
| E5-24 (THO1) - Body ground | 10 kΩ or higher |
| E4-28 (E2) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||