DTC B1651/33 Manual Cut off Switch Trouble |
| DTC No. | DTC Detecting Conditions | Trouble Areas |
| B1651/31 |
|
|

| 1.CHECK DTC |
![]() |
Turn the ignition switch to the ON position.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTION OF CONNECTORS |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor assembly and the airbag cut off switch.
|
| ||||
| OK | |
| 3.CHECK CONNECTORS |
Check that the connectors (on the center airbag sensor assembly side and airbag cut-off switch side) are not damaged (Click here).
|
| ||||
| OK | |
| 4.INSPECT AIRBAG CUT-OFF SWITCH |
![]() |
Disconnect the A20 airbag cut-off switch connector.
Measure the resistance.
| Switch Condition | Tester Condition | Specified Condition |
| OFF | 1(PMC+) - 2(PMC-) | 80 to 120 Ω |
| AUTO | 1(PMC+) - 2(PMC-) | 320 to 480 Ω |
|
| ||||
| OK | |
| 5.CHECK INSTRUMENT PANEL WIRE (FOR OPEN) |
![]() |
Disconnect the instrument panel wire connector from the airbag cut off switch.
Using a service wire, connect A20-1 (PMC+) and A20-2 (PMC-) of connector C.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| A21-11 (MSW+) - A21-12 (MSW-) | Always | Below 1Ω |
|
| ||||
| OK | |
| 6.CHECK INSTRUMENT PANEL WIRE (FOR SHORT) |
![]() |
Disconnect the service wire from connector C.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| A21-11 (MSW+) - A21-12 (MSW-) | Always | 1 MΩ or Higher |
|
| ||||
| OK | |
| 7.CHECK INSTRUMENT PANEL WIRE (TO B+) |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage.
| Tester Connection | Condition | Specified Condition |
| A21-11 (MSW+) - Body ground | Ignition switch ON | Below 1 V |
| A21-12 (MSW-) - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| OK | |
| 8.CHECK INSTRUMENT PANEL WIRE (TO GROUND) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| A21-11 (MSW+) - Body ground | Always | 1 MΩ or Higher |
| A21-12 (MSW-) - Body ground | Always | 1 MΩ or Higher |
|
| ||||
| OK | |
| 9.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the center airbag sensor assembly and airbag cut off switch.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||