DTC B1662/45 Indicator Light Circuit Malfunction |
| DTC No. | DTC Detecting Conditions | Trouble Areas |
| B1622/45 |
|
|

| 1.CHECK DTC |
![]() |
Turn the ignition switch to the ON position.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTORS |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor assembly and the combination meter assembly.
|
| ||||
| OK | |
| 3.CHECK CONNECTORS |
Check that the connectors (on the center airbag sensor assembly side and combination meter side) are not damaged (Click here).
|
| ||||
| OK | |
| 4.CHECK INSTRUMENT PANEL WIRE (FOR OPEN) |
![]() |
Disconnect the connectors from the center airbag sensor assembly and the combination meter.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| A21-14 (LA) - C9-33 | Always | Below 1 Ω |
|
| ||||
| OK | |
| 5.CHECK INSTRUMENT PANEL WIRE (TO GROUND) |
![]() |
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| A21-14 (LA) - Body ground | Always | 1 MΩ or Higher |
|
| ||||
| OK | |
| 6.CHECK INSTRUMENT PANEL WIRE (TO B+) |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage.
| Tester Connection | Condition | Specified Condition |
| A21-14 (LA) - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| OK | |
| 7.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Replace the center airbag sensor assembly (Click here).
Connect the connectors to the center airbag sensor assembly and the combination meter assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||