VOLTAGE INVERTER > INSPECTION |
| 1. INSPECT VOLTAGE INVERTER ASSEMBLY |

| Tester Connection | Condition | Specified Condition |
| +B(L2-2)-PGND(L2-1) | IG switch ON | 10 to 14V |
| AC1(L1-5)-PGND(L2-1) | IG switch ON, main switch ON | Pulse generation |
| P/T(L1-1)-Body Ground | Always | Below 1 Ω |
| AC2(L1-11)-PGND(L2-1) | IG switch ON, main switch ON | Pulse generation |