Home › BODY ELECTRICAL › LIGHTING › TURN SIGNAL FLASHER ASSEMBLY

TURN SIGNAL FLASHER ASSEMBLY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT TURN SIGNAL FLASHER ASSEMBLY (w/o Daytime Running Light System)


  1. Check the power source circuit and ground circuit.

    1. Remove the turn signal flasher assembly from the instrument panel junction block assembly.



    2. Measure the voltage and check the results in accordance with the value(s) in the table below.


      E076121E01


      Standard:

      Tester Connection
      Condition
      Specified Condition
      IA-4 - Body ground
      Ignition switch ON
      10 to 14 V
      IA-4 - Body ground
      Ignition switch OFF
      0 V
      IB-4 - Body ground
      Always
      10 to 14 V

    3. Measure the resistance and check the result in accordance with the value(s) in the table below.

      Standard:

      Tester Connection
      Condition
      Specified Condition
      IH-18 - Body ground
      Always
      Below 1 Ω



    E076122E01
  1. Check the output operation signal.

    1. Install the turn signal flasher assembly onto the instrument panel junction block assembly.

    2. Measure the voltage and check the results in accordance with the value(s) in the table below.

      Standard:

      Tester Connection
      Condition
      Specified Condition
      I1-11 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      I1-11 - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      I1-12 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      I1-12 - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      IJ-8 - Body ground
      Turn signal switch (left turn) OFF → ON
      10 to 14 V → 0 V
      IJ-18 - Body ground
      Turn signal switch (right turn) OFF → ON
      10 to 14 V → 0 V
      IJ-11 - Body ground
      Hazard switch OFF → ON
      10 to 14 V → 0 V



2. INSPECT TURN SIGNAL FLASHER ASSEMBLY (w/ Daytime Running Light System)


E076115E01
  1. Check the power source circuit and ground circuit.

    1. Disconnect the connector from the turn signal flasher assembly.

    2. Measure the voltage and check the results in accordance with the value(s) in the table below.

      Standard:

      Tester Connection
      Condition
      Specified Condition
      1 - Body ground
      Ignition switch ON
      10 to 14 V
      1 - Body ground
      Ignition switch OFF
      0 V
      6 - Body ground
      Always
      10 to 14 V

    3. Measure the resistance and check the result in accordance with the value(s) in the table below.

      Standard:

      Tester Connection
      Condition
      Specified Condition
      9 - Body ground
      Always
      Below 1 Ω



  1. Check the output operation signal.



      E076116E02
    1. Connect the connector to the turn signal flasher assembly.

    2. Measure the voltage and check the results in accordance with the value(s) in the table below.

      Standard:

      Tester Connection
      Condition
      Specified Condition
      2 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      2 - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      2 - Body ground
      Turn signal switch (right turn) ON → OFF
      10 to 14 V (60 to 120 times per minute) → 10 to 14 V
      3 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      3 - Body ground
      Turn signal switch (right turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      4 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      4 - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      4 - Body ground
      Turn signal switch (left turn) ON → OFF
      10 to 14 V (60 to 120 times per minute) → 10 to 14 V
      5 - Body ground
      Hazard switch OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      5 - Body ground
      Turn signal switch (left turn) OFF → ON
      0 V → 10 to 14 V (60 to 120 times per minute)
      7 - Body ground
      Turn signal switch (left turn) OFF → ON
      10 to 14 V → 0 V
      8 - Body ground
      Turn signal switch (right turn) OFF → ON
      10 to 14 V → 0 V
      10 - Body ground
      Hazard switch OFF → ON
      10 to 14 V → 0 V