Home › BODY ELECTRICAL › METER › COMBINATION METER

COMBINATION METER > DISASSEMBLY

for Preparation Click here



1. REMOVE BACK COVER


    B085805E01
  1. Remove the 3 screws.

  1. Using a screwdriver, disengage the 2 claws and remove the back cover.

    HINT:
    Tape up the screwdriver tip before use.



2. REMOVE COMBINATION METER GLASS


    B085818E01
  1. Using a screwdriver, disengage the 8 claws and remove the combination meter glass.

    HINT:
    Tape up the screwdriver tip before use.