AIR PUMP > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE AIR PUMP ASSEMBLY |
![]() |
Remove the 2 bolts, then separate the washer jar.
![]() |
Disconnect the air injection system No. 1 hose.
Disconnect the air pump connector and wire harness clamp.
![]() |
Remove the 3 bolts, then remove the air pump with bracket.
![]() |
Disconnect the air pump connector clamp.
Disengage the 3 fittings of the air pump insulator, and remove the air pump from the bracket.