AIR SWITCHING VALVE > INSTALLATION |
| 1. INSTALL AIR SWITCHING VALVE ASSEMBLY |
![]() |
Install a new gasket onto the cylinder head.
Install the air switching valve with the 2 nuts.
![]() |
Connect the air switching valve connector.
Connect the vacuum hose.
| 2. INSTALL INTAKE PIPE INSULATOR |
![]() |
Install 2 new gaskets onto the cylinder head and air switching valve.
Install the intake pipe insulator with the 4 nuts.
| 3. CONNECT AIR INJECTION SYSTEM NO.1 HOSE |
![]() |
Connect the air injection system No. 1 hose to the air switching valve.
| 4. INSTALL EXHAUST MANIFOLD HEAT INSULATOR NO.1 |
![]() |
Install the exhaust manifold heat insulator No. 1 with the 5 bolts.
| 5. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
![]() |
Install the air cleaner cap together with the air cleaner hose No. 1.
Connect the 2 air cleaner clamps.
Tighten the hose clamp bolt, then connect the air cleaner hose No. 1.
Connect the wire harness clamp.
Connect the mass air flow meter connector.
| 6. INSTALL INTAKE AIR CONNECTOR |
![]() |
Install the intake air connector with the 3 bolts.
Tighten the 2 hose clamp bolts.
![]() |
Connect the vacuum hose.
![]() |
Connect the ventilation hose No. 2.
![]() |
Connect the vacuum hose.
Engage the wire harness clamp.
Connect the pressure sensor connector.
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |