EMISSION CONTROL SYSTEM > ON-VEHICLE INSPECTION |
| 1. INSPECT AIR-FUEL RATIO COMPENSATION SYSTEM |
Measure the voltage between the terminals of the ECM connectors.
| Tester Connection | Condition | Specified Condition |
| B22 (A1A+) - A28 (E2) | Ignition switch ON | 3.3 V |
| B23 (A2A+) - A28 (E2) | Ignition switch ON | 3.3 V |
| B30 (A1A-) - A28 (E2) | Ignition switch ON | 2.9 V |
| B31 (A2A-) - A28 (E2) | Ignition switch ON | 2.9 V |

![]() |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / A/FS B1 S1 and O2S B1 S2.
Warm up the A/F sensor with the engine speed at 2,500 rpm for approximately 2 minutes.
![]() |
Maintain the engine speed at 2,500 rpm and confirm that the display on the intelligent tester, when A/FS B1 S1 is selected, is as shown in the illustration.
Confirm that the waveform displayed on the intelligent tester, when O2S B1 S2 is selected, changes between 0 V and 1 V with the engine speed at 2,500 rpm.
| 2. INSPECT FUEL CUT OFF RPM |
Increase the engine speed to at least 3,500 rpm.
Use a sound scope to check for injector operating sounds.
Check that injector operating sounds stop momentarily and then resume when the accelerator pedal is released.
| 3. VISUALLY INSPECT HOSES, CONNECTIONS AND GASKETS |
![]() |
Check the appearance.
Check if the indicated portions of the engine assembly are cracked, leaking or damaged.
| 4. INSPECT FUEL CUTOFF VALVE AND FILL CHECK VALVE |
![]() |
Remove the fuel tank (Click here).
Connect the pressure gauge to the vent hose port.
Install the fuel tank with the vent hose disconnected.
Fill the fuel tank with fuel.
Apply pressure at 4 kPa (41 gf/cm2, 0.58 psi) to the vent port of the fuel tank.
![]() |
Remove the fuel tank cap, and check that the pressure decreases.
If the pressure does not decrease, replace the fuel tank assembly.
Reconnect the vent line hose to the fuel tank.
| 5. CHECK AIR INLET LINE |
![]() |
Disconnect the air inlet line hose from the charcoal canister.
Check that air flows freely into the air inlet line.
If air does not flow freely into the air inlet line, repair or replace the air inlet line.
Reconnect the air inlet line hose to the charcoal canister.
| 6. INSPECT LEAK DETECTION PUMP (Pressure Sensor) |
![]() |
Measure the power source voltage of the ECM connectors.
| Tester Connection | Condition | Specified Condition |
| A23 (VC) - A28 (E2) | Ignition switch ON | 4.5 to 5.5 V |
Measure the power output of the ECM connectors.
Remove the fuel tank cap.
| Tester Connection | Condition | Specified Condition |
| E22 (PPMP) - A28 (E2) | Ignition switch ON | 1.425 to 4.150 V |
Install the fuel tank cap.