Home › ENGINE · 2TR-FE › STARTING › STARTER RELAY

STARTER RELAY > INSPECTION

for Preparation Click here



1. INSPECT STARTER RELAY


A097068E02
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard:
      Tester Connection
      Specified Condition
      3-5
      10kΩor higher
      3-5
      Below 1Ω(Apply battery voltage to terminals 1 and 2)

      If the result is not as specified, replace the starter relay.