GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using vernier calipers, measure the exposed brush length.
| 2. INSPECT GENERATOR REGULATOR ASSEMBLY |
![]() |
Using an ohmmeter, check the continuity between terminals F and B.
![]() |
Using an ohmmeter, check the continuity between terminals F and E.
| 3. INSPECT GENERATOR HOLDER WITH RECTIFIER |
![]() |
Using an ohmmeter, check the continuity between terminals P1, P2, P3, P4 and B, and between P1, P2, P3, P4 and E.
| Terminals | Specified Condition |
| P1, P2, P3, P4 and B | Continuity in one direction but no continuity in the other direction |
| P1, P2, P3, P4 and E | Continuity in one direction but no continuity in the other direction |
| 4. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check for open in the generator rotor circuit.
Using an ohmmeter, measure the resistance between the slip rings.
![]() |
Check for short in the generator rotor circuit.
Using an ohmmeter, check that there is no continuity between the slip ring and generator rotor assembly.
If there is continuity, replace the generator rotor assembly.
Inspect slip rings.
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
![]() |
Using vernier calipers, measure the slip ring diameter.