Home › ENGINE · 1GR-FE › CHARGING › GENERATOR (for BOSCH Made)

GENERATOR (for BOSCH Made) > INSPECTION

for Preparation Click here



1. INSPECT GENERATOR ROTOR ASSEMBLY


A095742E01
  1. Inspect the generator rotor assembly for an open circuit.

    1. Using an ohmmeter, measure the resistance between the slip rings.

      Standard:
      1.8 to 2.8 Ω at 20°C(68°F)

      If the result is not as specified, replace the generator rotor.



    A095743E01
  1. Inspect the generator rotor assembly for ground.

    1. Using an ohmmeter, measure the resistance between the slip ring and generator rotor assembly.

      Standard:
      10 kΩ or higher

      If the result is not as specified, replace the generator rotor.



    A095744E01
  1. Check the appearance.

    1. Check that the slip rings are not rough or scored.
      If rough or scored, replace the generator rotor.

    2. Using vernier calipers, measure the slip ring diameter.

      Standard diameter:
      15.3 to 15.5 mm (0.602 to 0.610 in.)

      Minimum diameter:
      14.9 mm (0.587 in.)

      If the diameter is less than the minimum, replace the generator rotor.



2. INSPECT STATOR SUB-ASSEMBLY GENERATOR WITH RECTIFIER


HINT:
For terminal positions of the stator generator, refer to the illustration below.



A095745E01



    A095746E01
  1. Inspect the positive (+) rectifier.

    HINT:
    Inspect the positive terminal after pulling it up.


    1. Using an ohmmeter, connect the positive (+) tester probe to the positive (+) terminal and the negative (-) tester probe to each rectifier terminal.

    2. Measure the resistance between the positive (+) terminal and rectifier terminal.

      Standard:
      Below 1 Ω

      If the result is not as specified, replace the stator generator.

    3. Reverse the polarity of the tester probes and repeat step (1).

    4. Measure the resistance between the positive (+) terminal and rectifier terminal.

      Standard:
      10 kΩ or higher

      If the result is not as specified, replace the stator generator.



    G036165E01
  1. Inspect the negative (-) rectifier.

    1. Using an ohmmeter, connect the positive (+) tester probe to each negative (-) terminal and the negative (-) tester prove to each rectifier terminal.

    2. Measure the resistance between the negative (-) terminal and rectifier terminal.

      Standard:
      10 kΩ or higher

      If the result is not as specified, replace the stator generator.

    3. Reverse the polarity of the tester probes and repeat step (1).

    4. Measure the resistance between the negative (-) terminal and rectifier terminal.

      Standard:
      Below 1 Ω

      If the result is not as specified, replace the stator generator.



    A095748E01
  1. Inspect the stator for an open circuit.

    1. Using an ohmmeter, measure the resistance between the rectifier terminals.

      Standard:
      Below 1 Ω

      If the result is not as specified, replace the stator generator.



3. INSPECT BRUSH


A095749E02
  1. Using vernier calipers, measure the brush length.

    Exposed length on new brush:
    13.2 mm (0.520 in.)

    Minimum exposed length:
    6 mm (0.236 in.)

    If the exposed length is less than the minimum, replace the voltage regulator and brush assembly.