GENERATOR (for BOSCH Made) > INSPECTION |
| 1. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Inspect the generator rotor assembly for an open circuit.
Using an ohmmeter, measure the resistance between the slip rings.
![]() |
Inspect the generator rotor assembly for ground.
Using an ohmmeter, measure the resistance between the slip ring and generator rotor assembly.
![]() |
Check the appearance.
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor.
Using vernier calipers, measure the slip ring diameter.
| 2. INSPECT STATOR SUB-ASSEMBLY GENERATOR WITH RECTIFIER |

![]() |
Inspect the positive (+) rectifier.
Using an ohmmeter, connect the positive (+) tester probe to the positive (+) terminal and the negative (-) tester probe to each rectifier terminal.
Measure the resistance between the positive (+) terminal and rectifier terminal.
Reverse the polarity of the tester probes and repeat step (1).
Measure the resistance between the positive (+) terminal and rectifier terminal.
![]() |
Inspect the negative (-) rectifier.
Using an ohmmeter, connect the positive (+) tester probe to each negative (-) terminal and the negative (-) tester prove to each rectifier terminal.
Measure the resistance between the negative (-) terminal and rectifier terminal.
Reverse the polarity of the tester probes and repeat step (1).
Measure the resistance between the negative (-) terminal and rectifier terminal.
![]() |
Inspect the stator for an open circuit.
Using an ohmmeter, measure the resistance between the rectifier terminals.
| 3. INSPECT BRUSH |
![]() |
Using vernier calipers, measure the brush length.