ROOM LIGHT ASSEMBLY > INSPECTION |
| 1. INSPECT ROOM LIGHT ASSEMBLY |
![]() |
Check the resistance.
Measure the resistance using an ohmmeter, and check the results in accordance with the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | OFF | 10 kΩ or higher |
| 1 - 3 | OFF | 10 kΩ or higher |
| 2 - 3 | OFF | 10 kΩ or higher |
| 1 - 2 | DOOR | Below 1 Ω |
| 1 - 3 | ON | Below 1 Ω |
Check the light operation.
Connect the battery positive (+) lead to terminal 1 and the battery negative (-) lead to terminal 2, then check that the light comes on when the switch is in the DOOR position.
Connect the battery positive (+) lead to terminal 1 and the battery negative (-) lead to terminal 3, then check that the light comes on when the switch is in the ON position.