Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2714    Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

C108924E05
The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the duty ratio* of the SLT solenoid valve output signal to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
*: The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio=A/(A+B) x 100 (%)

DTC No.
DTC Detection Condition
Trouble Area
P2714
ECM detects malfunctions on SLT (ON side) according to the revolution difference between the turbine and the output shaft, and also by monitoring the oil pressure. (2 trip detection logic)
  1. Shift solenoid valve SLT remains open or closed
  2. Shift solenoid valve S1, S2, SR, SL1 or SL2 remains open or closed
  3. Valve body is blocked
  4. Automatic transmission (clutch, brake or gear, etc.)

MONITOR DESCRIPTION

The ECM calculates the amount of heat absorbed by the friction material based on the difference in revolution (clutch slippage) between the turbine and output shaft. The ECM turns on the MIL and outputs this DTC when the amount of heat absorption exceeds the specified value.
When the shift solenoid valve SLT remains on, the oil pressure goes down and the clutch engagement force decreases.
NOTE: If driving continues under these conditions, the clutch will burn out and the vehicle will no longer be drivable.

MONITOR STRATEGY


Related DTCs
P2714 : Shift solenoid valve SLT/ON malfunction
Required sensors/Components (Main)
Shift solenoid valve SLT
Required sensors/Components (Related)
Valve body, ATF temperature sensor, Speed sensor (NT), Speed sensor (SP2)
Frequency of operation
Continuous
Duration
Immediate
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present.
None
Turbine speed sensor (NT) circuit
Functioning normally
Output speed sensor (SP2) circuit
Functioning normally
Transmission fluid temperature sensor "A" circuit
Functioning normally
Shift solenoid "A" (S1) circuit
Functioning normally
Shift solenoid "B" (S2) circuit
Functioning normally
Shift solenoid "E" (SR) circuit
Functioning normally
Pressure control solenoid "A" (SL1) circuit
Functioning normally
Pressure control solenoid "B" (SL2) circuit
Functioning normally
Pressure control solenoid "D" (SLT) circuit
Functioning normally
ECT (Engine coolant temperature) sensor circuit
Functioning normally
Knock sensor circuit
Functioning normally
ETCS (Electronic throttle control system)
System not down
Transmission shift position
"D"
ECT
40°C (104°F) or more
Spark advance from max. retard timing by knock sensor control
0° CA or more
Engine
Starting
ATF temperature
10°C (50°F) or more

TYPICAL MALFUNCTION THRESHOLDS


Summation of C1 clutch heat generations
= SUM (Turbine speed - Output speed x Temporary gear ratio)
Specified value

INSPECTION PROCEDURE

HINT:
Performing the ACTIVE TEST using the intelligent tester allows components, such as the relay, VSV, and actuator, to be operated without removing any parts. Performing the ACTIVE TEST as a first step of troubleshooting is one method of shortening labor time.
It is possible to display the DATA LIST during the ACTIVE TEST.
  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
  4. Turn the ignition switch to the ON position.
  5. Push the "ON" button of the tester.
  6. Clear the DTC.
  7. Select the items "DIAGNOSIS/ ENHANCED OBD II/ ACTIVE TEST/ LINE PRESS UP".
  8. According to the display on the tester, perform the "ACTIVE TEST".

    Item
    Test Details
    Diagnostic Note
    LINE PRESS UP *
    [Test Details]
    Operate the shift solenoid SLT to raise the line pressure.
    [Vehicle Condition]
    1. Vehicle Stopped
    2. IDL: ON
    [HINT]
    OFF: Line pressure up (When the active test of "LINE PRESS UP" is performed the ECM commands the SLT solenoid to turn off).
    ON: No action (normal operation)
    -
    *: "LINE PRESS UP" in the ACTIVE TEST is performed to check the line pressure changes by connecting SST to the automatic transmission, which is used in the HYDRAULIC TEST (Click here) as well.

HINT:
  1. The pressure values in ACTIVE TEST and HYDRAULIC TEST are different from each other.
  2. Normally, the line pressure detected in the ACTIVE TEST is approximately half of the value detected in the HYDRAULIC TEST's stall test.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P2714)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and push the intelligent tester main switch ON.

  1. Select the items "DIAGNOSIS/ ENHANCED OBD II/ DTC INFO/ CURRENT CODES".

  1. Read the DTCs using the intelligent tester.

    Result: 
    Display (DTC Output)
    Proceed to
    Only "P2714" is output
    A
    "P2714" and other DTCs
    B

    HINT:
    If any codes besides "P2714" are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART
A


2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (LINE PRESS UP)
G020657E01

NOTICE:
  1. Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F).
  2. Be careful to prevent SST's hose from interfering with the exhaust pipe.
  3. Perform the test with the A/C OFF.

HINT:
Performing the intelligent tester's ACTIVE TEST allows relay, VSV, actuator and other items to be operated without removing any parts. Performing the ACTIVE TEST early in troubleshooting is one way to save time.
The DATA LIST can be displayed during the ACTIVE TEST.

  1. Remove the test plug on the transmission case center right side and connect SST.

SST
09992-00095   (09992-00231, 09992-00271)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and warm it up.

  1. Measure the line pressure with SST.

  1. Turn the intelligent tester ON.

  1. Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST.

  1. Follow the instructions on the tester and perform the ACTIVE TEST.

  1. Measure the line pressure with SST.

    Item
    Test Details
    Diagnostic Note
    LINE PRESS UP*
    [Test Details]
    Operate shift solenoid SLT and raise line pressure.
    [Vehicle Condition]
    1. Vehicle stopped
    2. IDL: ON

    HINT:
    OFF: Line pressure up (when Active Test of "LINE PRESS UP" is performed, ECM commands SLT solenoid to turn OFF)
    ON: No action (normal operation)

    -
    *: "LINE PRESS UP" in the ACTIVE TEST is performed to check the line pressure changes by connecting SST to the automatic transmission, which is used in the HYDRAULIC TEST (Click here) as well. Please note that the pressure values in the ACTIVE TEST and HYDRAULIC TEST are different.



NG
Go to step 9
OK


3.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch ON.

  1. Turn the intelligent tester ON.

  1. Clear the DTC (Click here).

  1. Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST.

  1. Follow the instructions on the tester and perform the ACTIVE TEST.

HINT:
While driving, the shift position can be forcibly changed with the intelligent tester.


Item
Test Details
Diagnostic Note
SHIFT
[Test Details]
Operate the shift solenoid valve and set each shift position.
[Vehicle Condition]
  1. IDL: ON
  2. Less than 30 mph (50 km/h)
[Other information]
  1. Press "→" button: Shift up
  2. Press "←" button: Shift down
The operation of the shift solenoid valves can be checked.

HINT:
  1. This test can be conducted when the vehicle speed is 30 mph (50 km/h) or less.
  2. The 4th to 5th up-shift must be performed with the accelerator pedal released.
  3. The 5th to 4th down-shift must be performed with the accelerator pedal released.
  4. Do not operate the accelerator pedal for at least 2 seconds after shifting and do not shift successively.
  5. The shift position commanded by the ECM is shown in the DATA LIST (SHIFT) display on the intelligent tester.

  1. Compare the ECM gear shift command and the actual gear position.

    ECM gear shift command
    1st
    2nd
    3rd
    4th
    5th
    Proceed to
    Actual gear position under malfunction
    Shift solenoid S1
    Stuck ON
    1st
    2nd
    2nd
    1st
    N*1
    A
    Stuck OFF
    4th
    3rd
    3rd
    4th
    5th
    Shift solenoid S2
    Stuck ON
    2nd
    2nd
    3rd
    3rd
    N*1
    B
    Stuck OFF
    1st
    1st
    4th
    4th
    5th
    Shift solenoid SL2
    Stuck ON
    1st
    2nd
    3rd
    4th
    N*1
    C
    Stuck OFF
    1st
    2nd
    3rd
    4th
    5th
    Shift solenoid SR
    Stuck ON*2
    1st
    2nd
    3rd
    4th
    5th
    D
    Stuck OFF
    1st
    2nd
    3rd
    4th
    4th

    HINT:
    1. *1: Neutral
    2. *2: Shift shock increases extremely when a malfunction occurs.
    3. Gear shift can be determined by paying attention to changes in rpm.



B
Go to step 5

C
Go to step 6

D
Go to step 7

OK
Go to step 9
A


4.INSPECT SHIFT SOLENOID VALVE S1


    A110986E04
  1. Remove the shift solenoid valve S1.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating noise.



OK
Go to step 10
NG

REPLACE SHIFT SOLENOID VALVE S1 

5.INSPECT SHIFT SOLENOID VALVE S2


    A110987E04
  1. Remove the shift solenoid valve S2.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (S2) - Solenoid Body (S2)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating noise.



OK
Go to step 10
NG

REPLACE SHIFT SOLENOID VALVE S2 

6.INSPECT SHIFT SOLENOID VALVE SL2


    D025466E25
  1. Remove the shift solenoid valve SL2.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating noise.



OK
Go to step 10
NG

REPLACE SHIFT SOLENOID VALVE SL2 

7.INSPECT SHIFT SOLENOID VALVE SR


    A110988E05
  1. Remove the shift solenoid valve SR.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (SR) - Solenoid Body (SR)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SR
OK


8.INSPECT SHIFT SOLENOID VALVE SL1


    D025466E24
  1. Remove the shift solenoid valve SL1.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating noise.



OK
Go to step 10
NG

REPLACE SHIFT SOLENOID VALVE SL1 

9.INSPECT SHIFT SOLENOID VALVE SLT


    G020767E36
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK


10.INSPECT TRANSMISSION VALVE BODY ASSEMBLY (See chapter 2 in the problem symptoms table)

OK:
There are no foreign objects on any valves and they operate smoothly.



NG
REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY
OK


11.INSPECT TORQUE CONVERTER CLUTCH ASSEMBLY
  1. Check the torque converter clutch assembly (Click here).

    OK:
    The torque converter clutch operates normally.



NG
REPLACE TORQUE CONVERTER CLUTCH ASSEMBLY
OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY