DTC P0710 Transmission Fluid Temperature Sensor "A" Circuit |
DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0710 | (a) and (b) are detected momentarily within 0.5 seconds when neither P0712 nor P0713 is detected (1-trip detection logic)
Within 0.5 seconds, the malfunction changes from (a) to (b) or from (b) to (a) |
|
| P0712 | No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic) |
|
| P0713 | No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more 15 minutes or more after starting engine (1-trip detection logic) |
|
| Related DTCs | P0710: ATF temperature sensor/Range check (Fluttering) P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| Time after engine start | 15 minutes or more |
| ATF temperature sensor resistance | Less than 79 Ω or More than 156 kΩ |
| ATF temperature sensor resistance | Less than 79 Ω |
| ATF temperature sensor resistance | More than 156 kΩ |
| ATF temperature sensor | Atmospheric temperature up to approximately 130°C (266°F) |

| Item | Measurement Item/ Range (display) | Normal Condition |
| AT OIL TEMP1 | No. 1 ATF Temperature Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance.
| Tester Connection | Specified Condition |
| 2 (OT-) - 10 (OT+) | 79 Ω to 156 kΩ |
Measure the resistance.
| Tester Connection | Specified Condition |
| 2 (OT-) - Body ground | 10 kΩ or higher |
| 10 (OT+) - Body ground | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 20°C (68°F) | 3 to 4 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connectors.
Measure the resistance.
| Tester Connection | Specified Condition |
| E5-24 (THO1) - E4-28 (E2) | 79 Ω to 156 kΩ |
Measure the resistance.
| Tester Connection | Specified Condition |
| E5-24 (THO1) - Body ground | 10 kΩ or higher |
| E4-28 (E2) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||