Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0976    Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

DTC    P0977    Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves S1, S2, SR, SL1 and SL2 which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly (Click here).

DTC No.
DTC Detection Conditions
Trouble Areas
P0976
ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1-trip detection logic)
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977
ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1-trip detection logic)
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuits, the ECM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is on, if the resistance is 8 Ω or less, the ECM determines that there is a short malfunction in the shift solenoid valve S2 circuit.
When the shift solenoid valve S2 is off, if the resistance is 100 kΩ or more, the ECM determines that the shift solenoid valve S2 circuit is open (Click here).

MONITOR STRATEGY


Related DTCs
P0976: Shift solenoid valve S2/Range check (Low resistance)
P0977: Shift solenoid valve S2/Range check (High resistance)
Required sensors/Components
Shift solenoid valve S2
Frequency of operation
Continuous
Duration
0.064 seconds
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


P0976: Range check (Low resistance) 
The monitor will run whenever the following DTCs are not present.
None
Shift solenoid valve S2
ON

P0977: Range check (High resistance) 
The monitor will run whenever the following DTCs are not present.
None
Shift solenoid valve S2
OFF

TYPICAL MALFUNCTION THRESHOLDS


P0976: Range check (Low resistance) 
Shift solenoid valve S2 resistance
8 Ω or less

P0977: Range check (High resistance) 
Shift solenoid valve S2 resistance
100 kΩ or more

COMPONENT OPERATING RANGE


Shift solenoid valve S2 resistance
11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C124519E02


INSPECTION PROCEDURE


HINT:
The shift solenoid valve S2 is turned on/off normally when the shift lever is in the D position:

Gearshift controlled by ECM
1st
2nd
3rd
4th
5th
Shift solenoid valve S2
OFF
ON
ON
OFF
OFF

1.INSPECT TRANSMISSION WIRE (S2)


    G020667E63
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    15 - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G035616E30
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E5-10 (S2) - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE S2


    A110987E04
  1. Remove the shift solenoid valve S2.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (S2) - Solenoid Body (S2)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE S2
OK

REPAIR OR REPLACE TRANSMISSION WIRE