DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

Refer to DTC P2714 .

DTC No.
DTC Detection Conditions
Trouble Areas
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic)
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the linear solenoid valve (SLT) circuit, the ECM interprets this as a fault.
The ECM turns on the MIL and stores the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present.
None
Battery voltage
10 V or more
CPU requested duty ratio to SLT
Less than 75 %
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Output signal duty
100 %

COMPONENT OPERATING RANGE


Output signal duty ratio
Less than 100 %

WIRING DIAGRAM


C124520E03


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)


    G020667E65
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Measure the resistance.

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    14 (SLT+) - Body ground
    10 kΩ or higher
    6 (SLT-) - Body ground
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G035616E45
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E5-13 (SLT+) - E5-12 (SLT-)
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Measure the resistance.

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    E5-13 (SLT+) - Body ground
    10 kΩ or higher
    E5-12 (SLT-) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SLT


    G020767E36
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK