Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0748    Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves S1, S2, SR, SL1 and SL2 which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be driven smoothly (Click here).

DTC No.
DTC Detection Conditions
Trouble Areas
P0748
The ECM checks for an open or short in the shift solenoid valve SL1 circuit (1-trip detection logic)
  1. Output signal duty equals to 100 %.
    (NOTE: SL1 output signal duty is less than 100 % under normal condition.)
  1. Open or short in shift solenoid valve SL1 circuit
  2. Shift solenoid valve SL1
  3. ECM

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM controls the gearshift by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other functioning shift solenoid valves "ON/OFF". (If an open or short circuit is detected, the ECM cuts the current to the circuit.)
If the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines that there is a malfunction (Click here).

MONITOR STRATEGY


Related DTCs
P0748 : Shift solenoid valve SL1/Range check
Required sensors/Components
Shift solenoid valve SL1
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present.
None
Battery voltage
10 V or more
CPU commanded duty
Less than 75 %
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Output signal duty
100 %

COMPONENT OPERATING RANGE


Output signal duty
Less than 100 %

WIRING DIAGRAM


C124518E07


INSPECTION PROCEDURE


HINT:
The shift solenoid valve SL1 is turned on/off normally when the shift lever is in the D position:

Gearshift controlled by ECM
1st
2nd
3rd
4th
5th
Shift solenoid valve SL1
OFF
OFF
OFF
OFF
ON

1.INSPECT TRANSMISSION WIRE (SL1)


    G020667E60
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    12 (SL1+) - 4 (SL1-)
    5.0 to 5.6 Ωat 20°C (68°F)

  1. Measure the resistance.

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    12 (SL1+) - Body ground
    10 kΩ or higher
    4 (SL1-) - Body ground
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    G035616E46
  1. Connect the transmission connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E5-19 (SL1+) - E5-18 (SL1-)
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Measure the resistance.

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    E5-19 (SL1+) - Body ground
    10 kΩ or higher
    E5-18 (SL1-) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SL1


    D025466E24
  1. Remove the shift solenoid valve SL1.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    5.0 to 5.6 Ω at 20°C (68°F)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SL1
OK

REPAIR OR REPLACE TRANSMISSION WIRE