DTC P2740 Transmission Fluid Temperature Sensor "B" Circuit |
DTC P2742 Transmission Fluid Temperature Sensor "B" Circuit Low Input |
DTC P2743 Transmission Fluid Temperature Sensor "B" Circuit High Input |
| No.2 ATF Temperature Sensor Status | Detection Condition | Symptom | Recovery Condition |
| Sensor is normal |
|
|
|
|
|
| |
When the conditions (a) and (b) are satisfied continually
|
|
| |
| Sensor is short |
|
|
|
|
|
|
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P2740 | Conditions (a) and (b) are detected momentarily within 0.5 seconds when neither P2742 nor P2743 is detected (1-trip detection logic)
|
|
| P2742 | No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V) for 0.5 seconds or more (1-trip detection logic) |
|
| P2743 | No. 2 ATF temperature sensor resistance (voltage) is more than 156 kΩ (4.915 V) for 0.5 seconds or more 15 minutes or more after starting engine (1-tip detection logic) |
|
| Related DTCs | P2740 : No. 2 ATF temperature sensor/Range check (Fluttering) P2742 : No. 2 ATF temperature sensor/Range check (Low voltage) P2743 : No. 2 ATF temperature sensor/Range check (High voltage) |
| Required sensors/Components | No. 2 ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever the following DTCs are not present. | None |
| Time after engine start | 15 minutes or more |
| No. 2 ATF temperature sensor voltage | Less than 0.046 V or More than 4.915 V |
| No. 2 ATF temperature sensor voltage | Less than 0.046 V |
| No. 2 ATF temperature sensor voltage | More than 4.915 V |
| ATF temperature sensor | Atmospheric temperature up to approximately 130°C (266°F) |

| Item | Measurement Item/ Range (display) | Normal Condition |
| AT OIL TEMP2 | No. 2 ATF Temperature Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (NO.2 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance.
| Tester Connection | Specified Condition |
| 1 (OT2-) - 9 (OT2+) | 79 Ω to 156 kΩ |
Measure the resistance.
| Tester Connection | Specified Condition |
| 1 (OT2-) - Body ground | 10 kΩ or higher |
| 9 (OT2+) - Body ground | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 20°C (68°F) | 3 to 4 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connectors.
Measure the resistance.
| Tester Connection | Specified Condition |
| E5-32 (THO2) - E4-28 (E2) | 79 Ω to 156 kΩ |
Measure the resistance.
| Tester Connection | Specified Condition |
| E5-32 (THO2) - Body ground | 10 kΩ or higher |
| E4-28 (E2) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||