CAN COMMUNICATION SYSTEM > Can Main Bus Line for Disconnection |
| Symptom | Trouble Area |
| Resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is more than 69 Ω. |
|

| 1.CHECK DLC3 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified value | Result |
| D4-6 (CANH) - D4-14 (CANL) |
| 108 to 132 Ω | A |
| D4-6 (CANH) - D4-14 (CANL) |
| 132 Ω or higher | B |
|
| ||||
| A | |
| 2.CHECK CAN MAIN BUS LINE FOR DISCONNECTION (ECM - CAN J/C) |
![]() |
Disconnect the connector (E7) from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E7-33 (CANH) - E7-34 (CANL) |
| 108 to 132 Ω |
|
| ||||
| NG | |
| 3.INSPECT CAN J/C |
![]() |
Disconnect the CAN main bus line connector (J10) from the CAN J/C.
![]() |
Measure the resistance according to the value in the table below.
| Between the terminals where the connector (J10) was connected | Condition | Specified value |
| CANH - CANL |
| 108 to 132 Ω |
|
| ||||
| OK | ||
| ||