Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2TR-FE EMISSION CONTROL

2TR-FE EMISSION CONTROL > SERVICE DATA



Duty vacuum switching valve
Resistance
1 - 2
26 to 30 Ω at 20°C (68°F)
1 - Body
10 MΩ or higher
2 - Body
10 MΩ or higher
Air fuel ratio sensor
Resistance
1 (HT) - 2 (+B)
1.8 to 3.4 Ω at 20°C (68°F)
1 (HT) - 4 (AF-)
10 kΩ or higher
Heated oxygen sensor
Resistance
1 (HT) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT) - 4 (E)
10 kΩ or higher
Pressure sensor
Voltage
VC - E2
4.5 to 5.5 V
Air switching valve assembly
Resistance
1 - 2
4.5 to 5.5 Ω at 20°C (68°F)
Air pump assembly
Resistance
1 - 2
0.4 to 1.0 Ω at 20°C (68°F)