Air-fuel ratio compensation system
| Voltage
| B22 (A1A+) - A28 (E2)
| 3.3 V
|
B23 (A2A+) - A28 (E2)
| 3.3 V
|
B30 (A1A-) - A28 (E2)
| 2.9 V
|
B31 (A2A-) - A28 (E2)
| 2.9 V
|
Fuel cut off rpm
| Cut off
| 2,500 rpm
|
Return
| 1,400 rpm
|
Lead detection pump
| Voltage
| A23 (VC) - A28 (E2)
| 4.5 to 5.5 V
|
E22 (PPMP) - A28 (E2)
| 1.425 to 4.150 V
|
Vacuum Switching Valve No. 1
| Resistance
| at 20 °C (68 °F)
| 26 to 30 Ω
|
Air fuel ratio sensor (Bank 1, Bank 2)
| Resistance
| 1 (HT) - 2 (+B)
| 1.8 to 3.4 Ω at 20°C (68°F)
|
1 (HT) - 4 (E1)
| 10 kΩ or higher
|
Heated oxygen sensor No. 2 (Bank 1, Bank 2)
| Resistance
| 1 (HT) - 2 (+B)
| 11 to 16 Ω at 20°C (68°F)
|
Resistance
| 1 (HT) - 4 (E1)
| 10 kΩ or higher
|