Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0455    Evaporative Emission Control System Leak Detected (Gross Leak)

DTC    P0456    Evaporative Emission Control System Leak Detected (Very Small Leak)

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P0455
EVAP gross leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured.
Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that EVAP system has large leak.
  1. Fuel cap (loose)
  2. Leak from EVAP line
    (Canister assembly - Fuel tank)
  3. Leak from EVAP line
    (Purge VSV - Canister assembly)
  4. Canister pump module
  5. Leak from fuel tank
  6. Leak from canister assembly
While ignition switch off
2 trip
P0456
EVAP small leak
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured.
Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than second reference pressure, ECM determines that EVAP system has small leak.
While ignition switch off
2 trip

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned off.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B
First reference pressure measurement
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
10 seconds
E
Second reference pressure measurement
After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


A112612E37


Text in Illustration 
*1
Purge VSV: OFF (closed)
*2
Purge VSV: ON (open)
*3
Vent Valve: OFF (vent)
*4
Vent Valve: ON (closed)
*5
Leak Detection Pump: OFF
*6
Leak Detection Pump: ON
*7
Reference Orifice (0.02 inch)
*8
Canister Pressure Sensor
*9
Canister
*10
Fuel Tank
*11
Canister Pump Module
*12
Canister Filter
*a
Operation A:
Atmospheric Pressure Measurement
*b
Operation B, E:
Reference Pressure Measurement
*c
Operation C:
EVAP System Pressure Measurement
*d
Operation D:
Purge VSV Monitor
*e
Atmospheric Pressure
*f
Negative Pressure
  1. P0455: EVAP gross leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second reference pressure x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leakage, illuminates the MIL and stores the DTC (2 trip detection logic).

  2. P0456: EVAP very small leak
    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than second reference pressure, the ECM determines that the EVAP system has a small leak, illuminates the MIL and stores the DTC (2 trip detection logic).


    A106061E42


MONITOR STRATEGY


Required Sensors/Components (Main)
Purge VSV
Canister pump module
Required Sensors/Components (Related)
-
Frequency of Operation
Once per driving cycle
Duration
Within 15 minutes (varies with amount of fuel in tank)
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs not stored
None

P0455 (Pattern 1), P0456 
Atmospheric pressure
70 to 110 kPa(abs) [525 to 825 mmHg(abs)]
Battery voltage
10.5 V or more
Vehicle speed
Less than 4 km/h (2.5 mph)
Ignition switch
OFF
Time after key off
5 or 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of the following conditions 1 and 2 set before key off
-
1. Duration that vehicle has been driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)

P0455 (Pattern 2) 
Atmospheric pressure
70 to 110 kPa(abs) [525 to 825 mmHg(abs)]
Battery voltage
10.5 V or higher
Vehicle speed
Less than 4 km/h (2.5 mph)
Ignition switch
OFF
Canister pressure sensor malfunction (P0452, P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of the following conditions 1 and 2 set before key off
-
1. Duration that vehicle has been driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 40°C (40 to 104°F)
Intake air temperature
4.4 to 40°C (40 to 104°F)

TYPICAL MALFUNCTION THRESHOLDS


P0455 (Pattern 1) 
EVAP pressure when vacuum introduction is complete
Higher than reference pressure x 0.2

P0455 (Pattern 2) 
EVAP pressure when vacuum introduction is complete
Higher than reference pressure x 0.2

P0456 
EVAP pressure when vacuum introduction is complete
Between reference pressure and reference pressure x 0.2

MONITOR RESULT

Refer to Checking Monitor Status (Click here).

CONFIRMATION DRIVING PATTERN

NOTICE:
  1. The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 19 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine during this operation.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON and turn the Techstream on.
  3. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the Techstream on.
  6. Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.
  7. After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  8. Input the DTC: P0455 or P0456.
  9. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit

    HINT:
    If the judgment result shows ABNORMAL, the system has a malfunction.

  10. If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


INSPECTION PROCEDURE

Refer to the EVAP System .