Home
›
ENGINE · 2TR-FE
›
ENGINE CONTROL SYSTEM
›
KNOCK SENSOR
KNOCK SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT KNOCK SENSOR
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
Standard:
Tester Connection
Specified Condition
1 (Ground) - 2 (Output)
120 to 280 kΩ at 20°C (68°F)
If the result is not as specified, replace the knock sensor.