Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › OCCUPANT CLASSIFICATION SYSTEM (for Bench Seat Type)

OCCUPANT CLASSIFICATION SYSTEM (for Bench Seat Type) > DATA LIST / ACTIVE TEST

for Preparation Click here


HINT:
By accessing the Data List displayed by the Techstream, values of switches and sensors can be checked without removing any parts. Reading the Data List as the first step of troubleshooting is one method to shorten diagnostic time.


DATA LIST FOR OCCUPANT CLASSIFICATION ECU
  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch to ON.

  3. Following the display on the Techstream screen, read the Data List.

    HINT:
    The Specified Condition for Zero Point Calibration in the table below must be satisfied when the zero point calibration is performed.


    Occupant Detection: 
    Tester Display
    Test Part
    Control Range
    Specified Condition for Zero Point Calibration
    Diagnostic Note
    Passenger Classification
    Passenger classification/
    NG: Data is not determined
    AM50: Adult is seated and seat is in rear position
    AF05: Adult is seated and seat is in front position
    CHILD: Child is seated
    OFF: Vacant
    AF05/AM50/CHILD/OFF
    OFF
    -
    Passenger Buckle SW
    Buckle switch (Passenger side)/
    Set: Passenger side seat belt is fastened
    Unset: Passenger side seat belt is unfastened
    NG: Data is not determined
    Unset/Set
    Unset
    -
    Seat position sensor position status
    Seat position/
    ON: Seat is in front position
    OFF: Seat is in rear position
    NG: Data is not determined
    ON/OFF
    ON/OFF
    -
    Pressure sensor output
    Pressure sensor output/
    Min.: 0
    Max.: 255
    0 to 210
    0 to 2
    -
    Filter pressure sensor output
    Filtered pressure sensor output/
    Min.: 0
    Max.: 255
    38 to 240
    38 to 75
    If value outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly.
    Thermistor temperature output
    Thermistor temperature output/
    Min.: -40°C (-40°F)
    Max.: 90°C (194°F)
    -40° to 85°C (-40° to 185°F)
    3° to 40°C (36° to 104°F)
    If value outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc.
    Weight threshold
    Weight threshold/
    Min.: 0
    Max.: 255
    36 to 67
    (reference value)
    36 to 67
    (reference value)
    -
    Filtered belt tension output
    Filtered belt tension output/
    Min.: 0
    Max.: 255
    39 to 229
    39 to 64
    (no load)
    -
    Empty threshold value from the seat factory
    Empty threshold value from seat factory/
    Min.: 0
    Max.: 255
    38 to 75
    38 to 75
    -
    Threshold value for adult passenger or not from the seat factory
    Threshold value for adult passenger or not from seat factory/
    Min.: 0
    Max.: 255
    43 to 64
    (reference value)
    43 to 64
    (reference value)
    -
    Number of Present DTC
    Number of present trouble codes/
    Min.: 0
    Max.: 255
    0
    0
    -
    Number of Past DTC
    Number of past trouble codes/
    Min.: 0
    Max.: 255
    0