DTC B1835/58 Short in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1836/58 Open in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1837/58 Short to GND in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1838/58 Short to B+ in Front Passenger Side Curtain Shield Squib Circuit |
| DTC No. | DTC Detections Conditions | Trouble Areas |
| B1835/58 |
|
|
| B1836/58 |
|
|
| B1837/58 |
|
|
| B1838/58 |
|
|

| 1.CHECK DTC |
Proceed to the appropriate step according to DTC readings.
If using the Techstream (read the 5-digit DTCs): Using the Techstream, check for DTCs (Click here).
| Result | Proceed to |
| B1835 is output. | A |
| B1836 is output. | B |
| B1837 is output. | C |
| B1838 is output. | D |
If not using the Techstream (read the 2-digit DTCs): Check for DTCs (Click here).
| Result | Proceed to |
| DTC 58 is output. | E |
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | |
| 2.CHECK CONNECTOR |
Check that the floor wire connector (on the curtain shield airbag assembly RH side) is not damaged.
|
| ||||
| OK | |
| 3.CHECK FLOOR WIRE (FOR SHORT) |
![]() |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - C17-2 (ICP-) | Always | 1 MΩ or higher |
|
| ||||
| NG | ||
| ||
| 4.CHECK FLOOR WIRE (FOR OPEN) |
![]() |
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - C17-2 (ICP-) | Always | Below 1 Ω |
|
| ||||
| NG | ||
| ||
| 5.CHECK FLOOR WIRE (TO GROUND) |
![]() |
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - Body ground | Always | 1 MΩ or higher |
| C17-2 (ICP-) - Body ground | Always | 1 MΩ or higher |
|
| ||||
| NG | ||
| ||
| 6.CHECK FLOOR WIRE (TO B+) |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - Body ground | Ignition switch ON | Below 1 V |
| C17-2 (ICP-) - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| NG | ||
| ||
| 7.CHECK CONNECTOR |
Check that the floor wire connector (on the curtain shield airbag assembly RH side) is not damaged.
|
| ||||
| OK | |
| 8.CHECK FLOOR WIRE |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - Body ground | Ignition switch ON | Below 1 V |
| C17-2 (ICP-) - Body ground | Ignition switch ON | Below 1 V |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - C17-2 (ICP-) | Always | Below 1 Ω |
| C17-1 (ICP+) - Body ground | Always | 1 MΩ or higher |
| C17-2 (ICP-) - Body ground | Always | 1 MΩ or higher |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| C17-1 (ICP+) - C17-2 (ICP-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 9.REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH (CURTAIN SHIELD AIRBAG (FRONT PASSENGER SEAT SIDE) SQUIB) |
![]() |
Replace the curtain shield airbag assembly RH (Click here).
Connect the connectors to the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 10.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| NG | ||
| ||
| 11.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Connect the connectors to the center airbag sensor assembly.
Using a service wire, connect C17-1 (ICP+) and C17-2 (ICP-) of connector C.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | |
| 12.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the service wire from connector C.
Connect the connector to the curtain shield airbag assembly RH.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear any DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||