AIR INLET CONTROL SERVO MOTOR > INSPECTION |
| 1. INSPECT AIR INLET CONTROL SERVO MOTOR |
![]() |
Inspect the servo motor operation.
Connect the positive (+) lead from the battery to terminal 1 (FRS) and negative (-) lead to terminals 2 (REC), then check that the shaft rotates clockwise smoothly.
Connect the positive (+) lead from the battery to terminal 2 (REC) and negative (-) lead to terminal 1 (FRS) then check that the shaft rotates counter clockwise smoothly.
If the operations are not as specified, replace the air control servo motor.