Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR MIX CONTROL SERVO MOTOR

AIR MIX CONTROL SERVO MOTOR > INSPECTION

for Preparation Click here



1. INSPECT AIR MIX CONTROL SERVO MOTOR


    I045423E02
  1. Inspect the servo motor operation.

    1. When 12 V is applied between terminals 4 (IGN) and 1 (GND), and 0V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 0V position.
      If the result is not as specified, replace the air mix control servo motor.

    2. When 12V is applied between terminals 4 (IGN) and 1 (GND), and 6V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 6V position.
      If the result is not as specified, replace the air mix control servo motor.

    3. When 12V is applied between terminals 4 (IGN) and 1 (GND), and between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 12V position.
      If the result is not as specified, replace the air mix control servo motor.