Home › BODY ELECTRICAL › AUDIO / VISUAL › NOISE FILTER (for 1GR-FE)

NOISE FILTER (for 1GR-FE) > INSTALLATION

for Preparation Click here



1. INSTALL RADIO SETTING CONDENSER


E075972
  1. Connect the connector.

  1. Wind new vinyl tape around the hose and install the radio setting condenser.



2. INSTALL AIR CLEANER ASSEMBLY
  1. Install the air cleaner with the 2 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

  1. Connect the ventilation hose No. 2.



3. INSTALL V-BANK COVER
  1. Install the V-bank cover with the 2 nuts.

    Torque:
    7.5 N*m{ 76 kgf*cm , 66 in.*lbf }



4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Torque:
5.4 N*m{ 55 kgf*cm , 48 in.*lbf }