Home › BODY ELECTRICAL › LIGHTING › HAZARD WARNING SWITCH

HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    E076077E02
  1. Check the resistance.
    Text in Illustration 
    *a
    Component without harness connected
    (Hazard Warning Switch)

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      7-9
      OFF
      10 kΩ or higher
      7-9
      ON
      Below 1 Ω

      If the result is not as specified, replace the hazard warning signal switch assembly.

  1. Check the illumination operation.

    1. Connect the battery positive (+) lead to terminal 11 and the battery negative (-) lead to terminal 10, then check that the illumination comes on.

      Standard:
      Illumination comes on.

      If the illumination does not come on, replace the bulb.