WIPER SWITCH > INSPECTION |
| 1. INSPECT WIPER SWITCH |
![]() |
Check the resistance.
Measure the resistance and check the results in accordance with the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| +B(E7-2) - +1(E7-3) | MIST | Below 1 Ω |
| +S(E7-1) - +1(E7-3) | OFF | Below 1 Ω |
| +S(E7-1) - +1(E7-3) | INTO | Below 1 Ω |
| +B(E7-2) - +1(E7-3) | LO | Below 1 Ω |
| +B(E7-2) - +2(E7-4) | HI | Below 1 Ω |
| Tester connection | Condition | Specified condition |
| EW(E11-2) - WF(E11-3) | OFF | 10 kΩ or higher |
| EW(E11-2) - WF(E11-3) | ON | Below 1 Ω |
Check the intermittent operation.
Connect the voltmeter positive terminal to terminal 3 (+1) of the E7 connector and the voltmeter negative terminal to terminal 2 (EW) of the E11 connector.
Connect the battery positive (+) lead to terminal 2 (+B) of the E7 connector and the battery negative (-) lead to terminals 2 (EW) of the E11 connector and 1 (+S) of the E7 connector.
Turn the wiper switch to the INT position.
Connect the battery positive (+) lead to terminal 1 (+S) of the E7 connector for 5 seconds.
Connect the battery negative lead to terminal 1 (+S) of the E7 connector. Operate the intermittent wiper relay and check the voltage between terminals 3 (+1) of the E7 connector and 2 (EW) of the E11 connector.

Check the operation

Turn the wiper switch off.
Connect the battery positive lead to terminal 2 (+B) of the E7 connector and the battery negative lead to terminals 1 (+S) of the E7 connector and 2 (EW) of the E11 connector.
Connect the voltmeter positive terminal to terminal 3 (+1) of the E7 connector and the voltmeter negative terminal to terminal 2 (EW) of the E11 connector. Turn the washer switch on and off, and check the voltage between terminals 3 (+1) of the E7 connector and 2 (EW) of the E11 connector.