Home › ENGINE ยท 2TR-FE › EMISSION CONTROL › AIR SWITCHING VALVE

AIR SWITCHING VALVE > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL


2. REMOVE INTAKE AIR CONNECTOR


G037694E01
  1. Disconnect the pressure sensor connector.

  1. Disengage the wire harness clamp.

  1. Disconnect the vacuum hose.



    G037695E01
  1. Disconnect the No. 2 ventilation hose.



    G037696E01
  1. Disconnect the vacuum hose.



    G037697E01
  1. Loosen the 2 hose clamp bolts.

  1. Remove the 3 bolts, then remove the intake air connector.



3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


G037934E01
  1. Disconnect the mass air flow meter connector.

  1. Disconnect the wire harness clamp.

  1. Loosen the hose clamp bolt, then disconnect the air cleaner hose No. 1.

  1. Disconnect the 2 air cleaner clamps.

  1. Remove the air cleaner cap together with the air cleaner hose No. 1.



4. REMOVE NO.1 EXHAUST MANIFOLD HEAT INSULATOR


G037935E01
  1. Remove the 5 bolts, then remove the exhaust manifold heat insulator No. 1.



5. DISCONNECT AIR INJECTION SYSTEM NO.1 HOSE


G037936E01
  1. Disconnect the air injection system No. 1 hose from the air switching valve.



6. REMOVE INTAKE PIPE INSULATOR


G037937E01
  1. Remove the 4 nuts, then remove the intake pipe insulator.

  1. Remove the 2 gaskets.



7. REMOVE AIR SWITCHING VALVE ASSEMBLY


G037938E01
  1. Disconnect the vacuum hose.

  1. Disconnect the air switching valve connector.



    G037939E01
  1. Remove the 2 nuts, then remove the air switching valve.

  1. Remove the gasket.