Home › BODY ELECTRICAL › LIGHTING › ROOM LIGHT ASSEMBLY

ROOM LIGHT ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT ROOM LIGHT ASSEMBLY


    E076078E07
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *a
    Component without harness connected
    (Room Light Assembly)

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 2
    OFF
    10 kΩ or higher
    1 - 3
    OFF
    10 kΩ or higher
    2 - 3
    OFF
    10 kΩ or higher

    If the result is not as specified, replace the room light assembly.

  1. Apply battery voltage to the connector and check the room light comes on.

    OK:
    Tester Connection
    Switch Condition
    Specified Condition
    Battery positive (+) → 1
    Battery negative (-) → 2
    OFF
    All light not comes on
    Battery positive (+) → 1
    Battery negative (-) → 3
    OFF
    All light not comes on
    Battery positive (+) → 1
    Battery negative (-) → 2
    ON
    All light not comes on
    Battery positive (+) → 1
    Battery negative (-) → 3
    ON
    Light comes on
    Battery positive (+) → 1
    Battery negative (-) → 2
    DOOR
    Light comes on
    Battery positive (+) → 1
    Battery negative (-) → 3
    DOOR
    All light not comes on

    If the result is not as specified, replace the room light bulb or room light assembly.