Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2757    Torque Converter Clutch Pressure Control Solenoid Performance (Shift Solenoid Valve SLU)

for Preparation Click here


DESCRIPTION

The ECM uses the signals from the throttle position sensor, air-flow meter, turbine (input) speed sensor, output speed sensor and crankshaft position sensor to monitor the engagement condition of the lock-up clutch.

C221407E04

Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect any mechanical problems with the shift solenoid valve SLU, valve body or torque converter.

DTC No.
DTC Detection Condition
Trouble Area
P2757
Lock-up does not occur when driving in the lock-up range
(normal driving at 80 km/h (50 mph)), or lock-up remains ON in the lock-up OFF range.
(2-trip detection logic)
  1. Shift solenoid valve SLU remains open or closed
  2. Valve body is blocked
  3. Shift solenoid valve SLU
  4. Torque converter assembly
  5. Automatic transmission (clutch, brake or gear, etc.)
  6. Line pressure is too low

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on turbine (input) speed sensor NT, output speed sensor SP2, engine rpm, engine load, engine coolant temperature, vehicle speed, transmission fluid temperature, and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) with the input turbine rpm (NT). The ECM calculates the actual transmission gear by comparing input turbine rpm (NT) with output shaft rpm (SP2). When the conditions are appropriate, the ECM requests "lock-up" by applying the control voltage to the shift solenoid SLU. When SLU is turned on, solenoid SLU applies pressure to the lock-up relay valve and locks the torque converter.
If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it is not requested, the ECM interprets this as a fault in the shift solenoid valve SLU or lock-up system performance. The ECM turns on the MIL and stores the DTC.
Example:
When any of the following are met, the ECM interprets it as a malfunction.
  1. There is a difference in rotation before and after the torque converter even when the ECM requests lock-up.
    (Engine speed is at least 70 rpm greater than the input turbine speed.)
  2. There is no difference in rotation before and after the torque converter even when the ECM requests lock-up off.
    (The difference between the engine speed and input turbine speed is less than 35 rpm.)

MONITOR STRATEGY


Related DTCs
P2757:
Shift solenoid valve SLU/OFF malfunction
Shift solenoid valve SLU/ON malfunction
Required sensors/Components
Shift solenoid valve SLU, Valve body, Vehicle speed sensor, Speed sensor (NT), Speed sensor (NO), Throttle position sensor
Frequency of operation
Continuous
Duration
OFF malfunction (A)
2 seconds
OFF malfunction (B)
0.4 seconds
ON malfunction
1.8 seconds
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever the following DTCs are not present
P0717 (Turbine speed sensor circuit)
P0722 (Output speed sensor circuit)
P0751, P0973, P0974 (Shift solenoid valve S1 circuit)
P0756, P0976, P0977 (Shift solenoid valve S2 circuit)
P0985, P0986 (Shift solenoid valve SR circuit)
P2759 (Torque converter clutch pressure control solenoid circuit)
P0327, P0328, P0332, P0333 (KCS sensor circuit)
P0776 (Shift solenoid valve SL2 circuit)
P0781 (1-2 shift valve circuit)
ETCS (Electric throttle control system)
Not system down
Transmission range
"D"
Duration time from shifting "N" to "D"
4 seconds or more
ECT
40°C (104°F) or more
Spark advance from Max. retard timing by KCS control
0° CA or more
Engine
Starting
ECM selected gear
2nd, 3rd, 4th or 5th
Vehicle speed
25 km/h (15.5 mph) or more
Transfer neutral position switch
OFF

OFF Malfunction (A) 
ECM lock-up command
ON (SLU pressure: 513 kPa (5.2 kgf/cm2, 74 psi) or more)
Vehicle speed
Less than 120 km/h (74.6 mph)

OFF Malfunction (B) 
ECM selected gear
2nd
Vehicle speed
2 km/h (1.2 mph) or more
Output speed
2nd → 1st down-shift point or more
Throttle valve opening angle
6.5% or more at 2000 rpm (Varies with engine speed)

ON Malfunction 
ECM lock-up command
OFF (SLU pressure: less than 4 kPa (0.04 kgf/cm2, 0.6 psi))
Throttle valve opening angle
7% or more
Vehicle speed
Less than 120 km/h (74.6 mph) at 4th gear (Varies with ECM selected gear)

TYPICAL MALFUNCTION THRESHOLDS

[OFF Malfunction]
  1. Both of the following conditions are met: OFF malfunction (A) and (B)

    OFF Malfunction (A) 
    Engine speed - Turbine speed (NE - NT)
    70 rpm or more

    OFF Malfunction (B) 
    Turbine speed/Output speed (NT/NO)
    Less than 3.30, or more than 7.50
[ON Malfunction]
  1. 2 detections are necessary per driving cycle:
    1st detection: temporary flag ON
    2nd detection: pending fault code ON
    Vehicle speed must be under 10 km/h (6.2mph) once before 2nd detection.

    Engine speed - Turbine speed (NE - NT)
    Less than 35 rpm

INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


ACTIVE TEST

HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the Techstream to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn the Techstream on.

  6. Enter the following menus: Powertrain / Engine and ECT / Active Test.

  7. According to the display on the Techstream, perform the Active Test.

    Engine and ECT 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Activate the Lock Up
    Control shift solenoid SLU to set automatic transmission to lock-up condition
    ON or OFF
    Possible to check shift solenoid valve SLU operation
    [Vehicle Condition]
    1. Throttle valve opening angle: Less than 35%
    2. Vehicle speed: 60 km/h (37 mph) or more

    HINT:
    This test can be conducted when the vehicle speed is 60 km/h (37 mph) or more.

  8. Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.

HINT:
  1. When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.

  2. Slowly release the accelerator pedal in order to decelerate, but do not fully release the pedal. (Fully releasing the pedal causes closure of the throttle valve and lock-up may be turned off automatically.)


    C124514E01

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P2757)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read the DTCs using the Techstream.
    Result 
    Result
    Proceed to
    Only P2757 is output
    A
    P2757 and other DTCs are output
    B

    HINT:
    If any codes besides P2757 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.INSPECT SHIFT SOLENOID VALVE SLU


    C151311E64
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLU
OK


3.INSPECT TRANSMISSION VALVE BODY ASSEMBLY (see chapter 2 in the Problem Symptoms Table)
  1. Check the transmission valve body assembly (Click here).

    OK:
    There are no foreign objects on any valves and they operate smoothly.



NG
REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY (Click here)
OK


4.INSPECT TORQUE CONVERTER ASSEMBLY
  1. Inspect the torque converter assembly (Click here).

    OK:
    The torque converter operates normally.



NG
REPLACE TORQUE CONVERTER ASSEMBLY
OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY (Click here)