VEHICLE STABILITY CONTROL SYSTEM (for Vacuum Brake Booster) > TERMINALS OF ECU |
| SKID CONTROL ECU |

| *a | Component without harness connected (Skid Control ECU (Brake Actuator Assembly)) | - | - |
| Terminal No. (Symbol) | Terminal Description |
| S1-1 (GND1) | Ground |
| S1-2 (STP) | Stop light switch input |
| S1-4 (RL-) | Rear wheel speed sensor LH signal input |
| S1-5 (RL+) | Rear wheel speed sensor LH power supply output |
| S1-6 (FR-) | Front wheel speed sensor RH signal input |
| S1-7 (FR+) | Front wheel speed sensor RH power supply output |
| S1-9 (EXI4) | L4 detection switch input*1 |
| S1-11 (SP1) | Speed signal output for speedometer |
| S1-12 (+BS) | Power supply for solenoid relay |
| S1-13 (GND2) | Ground |
| S1-14 (CANL) | CAN communication line L |
| S1-16 (RR-) | Rear wheel speed sensor RH signal input |
| S1-17 (RR+) | Rear wheel speed sensor RH power supply output |
| S1-18 (FL-) | Front wheel speed sensor LH signal input |
| S1-19 (FL+) | Front wheel speed sensor LH power supply output |
| S1-20 (EXI) | 4WD detection switch input*1 |
| S1-22 (STP2) | Stop light switch input*5 |
| S1-24 (BM) | Power supply for motor |
| S1-25 (CANH) | CAN communication line H |
| S1-26 (NEO) | 4WD identification signal input*1 |
| S1-28 (EXI3) | Differential lock indicator switch input *3 IG power supply *4 |
| S1-29 (PKB) | Parking brake switch input |
| S1-30 (CSW) | VSC OFF switch input |
| S1-31 (STPO) | Stop light operated relay output*5 |
| S1-32 (P) | Shift position indicator P signal input*2 |
| S1-33 (TS) | Sensor test terminal (Signal check switch) |
| S1-34 (IG1) | IG1 power supply |
| CHECK SKID CONTROL ECU |
Disconnect the S1 skid control ECU connector.
Measure the voltage or resistance according to the value(s) in the table below.

| *a | Front view of wire harness connector (Skid Control ECU (Brake Actuator Assembly)) | - | - |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
| S1-1 (GND1) - Body ground | W-B | Ground | Always | Below 1 Ω |
| S1-2 (STP) - Body ground | L | Stop light switch input | Stop light switch off (Brake pedal released) | Below 1.5 V |
| Stop light switch on (Brake pedal depressed) | 11 to 14 V | |||
| S1-9 (EXI4) - Body ground*1 | Y-B | L4 detection switch input | Ignition switch ON Transfer position in L4 | Below 1.5 V |
| Ignition switch ON Transfer condition not in L4 | 11 to 14 V | |||
| S1-12 (+BS) - Body ground | R | Power supply for solenoid relay | Always | 11 to 14 V |
| S1-13 (GND2) - Body ground | W-B | Ground | Always | Below 1 Ω |
| S1-20 (EXI) - Body ground*1 | LG-B | 4WD detection switch input | Ignition switch ON Transfer condition in H4 or L4 | Below 1.5 V |
| Ignition switch ON Transfer condition in H2 | 11 to 14 V | |||
| S1-22 (STP2) - Body ground*5 | L | Stop light switch input | Stop light switch off (Brake pedal released) | Below 1.5 V |
| Stop light switch on (Brake pedal depressed) | 8 to 14 V | |||
| S1-24 (BM) - Body ground | B | Power supply for motor | Always | 11 to 14 V |
| S1-26 (NEO) - Body ground*1 | W-B | 4WD identification signal input | Always | Below 1 Ω |
| S1-28 (EXI3) - Body ground*3 | L-Y | Differential lock indicator switch input | Ignition switch ON Differential lock switch on | Below 1.5 V |
| Ignition switch ON Differential lock switch off | 11 to 14 V | |||
| S1-28 (EXI3) - Body ground*4 | L-Y | IG power supply | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| S1-29 (PKB) - Body ground | G-Y | Parking brake switch input | Parking brake switch off | 10 kΩ or higher |
| Parking brake switch on | Below 1 Ω | |||
| S1-30 (CSW) - Body ground | GR-B | VSC OFF switch input | VSC OFF switch off | 10 kΩ or higher |
| VSC OFF switch on and held | Below 1 Ω | |||
| S1-31 (STPO) - Body ground*5 | G-B | Stop light operated relay output | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| S1-32 (P) - Body ground*2 | BR-W | Shift position indicator P signal input | Ignition switch ON Shift lever in P | 11 to 14 V |
| Ignition switch ON Shift lever in not P | Below 1 V | |||
| S1-34 (IG1) - Body ground | LG | IG power supply | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |