Home
›
BRAKE
›
BRAKE CONTROL
›
TRACTION OFF SWITCH
TRACTION OFF SWITCH > INSPECTION
for Preparation
Click here
1. INSPECT A-TRAC SWITCH
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Switch Condition
Specified Condition
5 - 8
Pressed
Below 1 Ω
Not pressed
10 kΩ or higher
If the value is not as specified, replace the A-TRAC switch.