METER / GAUGE SYSTEM > Entire Combination Meter does not Operate |

| 1.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND) |
![]() |
Disconnect the C9 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C9-1 - Body ground | Always | 11 to 14 V |
| C9-21 - Body ground | Ignition switch ON | 11 to 14 V |
Measure the resistance according to the value in the table below.
| Tester Connection | Condition | Specified Condition |
| C9-2 - Body ground | Always | Below 1 Ω |
| *a | Rear view of wire harness connector (to Combination Meter Assembly) |
Reconnect the combination meter assembly connector.
|
| ||||
| OK | ||
| ||