Air-fuel ratio compensation system
| Voltage
| E11-1 (A1A+) - E11-12 (E1)
| 3.3 V
|
E11-7 (A2A+) - E11-12 (E1)
| 3.3 V
|
E11-2 (A1A-) - E11-12 (E1)
| 2.9 V
|
E11-8 (A2A-) - E11-12 (E1)
| 2.9 V
|
Canister Pump Module (Pressure Sensor)
| Voltage
| E9-15 (VCV1) - E10-8 (ETHW)
| 4.5 to 5.0 V
|
E10-1 (PPMP) - E10-8 (ETHW)
| 3.0 to 3.6 V
|
Vacuum Switching Valve No. 1
| Resistance
| at 20 °C (68 °F)
| 26 to 30 Ω
|
Air fuel ratio sensor (Bank 1)
| Resistance
| 1 (HA1A) - 2 (+B)
| 1.8 to 3.4 Ω at 20°C (68°F)
|
1 (HA1A) - 4 (A1A-)
| 10 kΩ or higher
|
Air fuel ratio sensor (Bank 2)
| Resistance
| 1 (HA2A) - 2 (+B)
| 1.8 to 3.4 Ω at 20°C (68°F)
|
1 (HA2A) - 4 (A2A-)
| 10 kΩ or higher
|
Heated oxygen sensor No. 2 (Bank 1)
| Resistance
| 1 (HT1B) - 2 (+B)
| 11 to 16 Ω at 20°C (68°F)
|
Resistance
| 1 (HT1B) - 4 (E2)
| 10 kΩ or higher
|
Heated oxygen sensor No. 2 (Bank 2)
| Resistance
| 1 (HT2B) - 2 (+B)
| 11 to 16 Ω at 20°C (68°F)
|
Resistance
| 1 (HT2B) - 4 (E2)
| 10 kΩ or higher
|