Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1GR-FE EMISSION CONTROL

1GR-FE EMISSION CONTROL > SERVICE DATA



Air-fuel ratio compensation system
Voltage
E11-1 (A1A+) - E11-12 (E1)
3.3 V
E11-7 (A2A+) - E11-12 (E1)
3.3 V
E11-2 (A1A-) - E11-12 (E1)
2.9 V
E11-8 (A2A-) - E11-12 (E1)
2.9 V
Canister Pump Module (Pressure Sensor)
Voltage
E9-15 (VCV1) - E10-8 (ETHW)
4.5 to 5.0 V
E10-1 (PPMP) - E10-8 (ETHW)
3.0 to 3.6 V
Vacuum Switching Valve No. 1
Resistance
at 20 °C (68 °F)
26 to 30 Ω
Air fuel ratio sensor (Bank 1)
Resistance
1 (HA1A) - 2 (+B)
1.8 to 3.4 Ω at 20°C (68°F)
1 (HA1A) - 4 (A1A-)
10 kΩ or higher
Air fuel ratio sensor (Bank 2)
Resistance
1 (HA2A) - 2 (+B)
1.8 to 3.4 Ω at 20°C (68°F)
1 (HA2A) - 4 (A2A-)
10 kΩ or higher
Heated oxygen sensor No. 2 (Bank 1)
Resistance
1 (HT1B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
Resistance
1 (HT1B) - 4 (E2)
10 kΩ or higher
Heated oxygen sensor No. 2 (Bank 2)
Resistance
1 (HT2B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
Resistance
1 (HT2B) - 4 (E2)