Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2TR-FE COOLING

2TR-FE COOLING > SERVICE DATA



Thermostat
Valve opening temperature
80 to 84°C (176 to 183°F)
Valve lift
at 95°C (203°F)
8.5 mm (0.355 in.) or more
Radiator cap sub-assembly
Standard opening pressure
93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum opening pressure
78 kPa (0.8 kgf/cm2, 11.4 psi)