Home › BODY ELECTRICAL › LIGHTING › VANITY LIGHT

VANITY LIGHT > INSPECTION

for Preparation Click here



1. INSPECT VISOR ASSEMBLY RH


    E144193E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (SW) - 1 (GND)
    Visor raised
    10 kΩ or higher
    2 (SW) - 1 (GND)
    Visor lowered and mirror cover closed
    10 kΩ or higher
    2 (SW) - 1 (GND)
    Visor lowered and mirror cover open
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Visor Assembly RH)
    If the result is not as specified, there may be a malfunction in the visor assembly.



2. INSPECT VISOR ASSEMBLY LH


    E144193E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (SW) - 1 (GND)
    Visor raised
    10 kΩ or higher
    2 (SW) - 1 (GND)
    Visor lowered and mirror cover closed
    10 kΩ or higher
    2 (SW) - 1 (GND)
    Visor lowered and mirror cover open
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Visor Assembly LH)
    If the result is not as specified, there may be a malfunction in the visor assembly.