SFI SYSTEM > CHECKING MONITOR STATUS |
| PERFORM MONITOR DRIVE PATTERN |
Connect the Techstream to the DLC3.
Turn the ignition switch ON and the Techstream ON.
Clear DTCs (Click here).
Run the vehicle in accordance with the applicable drive pattern described in READINESS MONITOR DRIVE PATTERN (Click here). Do not turn the ignition switch OFF.
| ACCESS MONITOR RESULT |
Enter the following menus: Powertrain / Engine and ECT / Monitor / Result. The monitor status appears after the component name.
Confirm that the component is either Pass or Fail.
Select the component and press ENTER. The accuracy test value appears if the monitor status is either Pass or Fail.
| CHECK COMPONENT STATUS |
Compare the test value with the minimum test limit (MIN LIMIT) and maximum test limit (MAX LIMIT).
If the test value is between the minimum test limit and maximum test limit, the component is functioning normally. If not, the component is malfunctioning. The test value is usually significantly higher or lower than the test limit. If the test value is on the borderline of the test limit, the component will malfunction in the near future.
| MONITOR RESULT INFORMATION |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $01 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $01 | $91 | Multiply by 0.004 | mA | A/F sensor current |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $05 | $8E | Multiply by 0.001 | V | A/F sensor deterioration level |
| $05 | $91 | Multiply by 0.004 | mA | A/F sensor current |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $02 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $02 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $02 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $02 | $8F | Multiply by 0.0003 | g | Maximum oxygen storage capacity |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $06 | $07 | Multiply by 0.001 | V | Minimum sensor voltage |
| $06 | $08 | Multiply by 0.001 | V | Maximum sensor voltage |
| $06 | $8D | Multiply by 0.001 | Seconds | Duration that sensor voltage drops to 0.2 V during fuel cut |
| $06 | $8F | Multiply by 0.0003 | g | Maximum oxygen storage capacity |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $21 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst - Bank 1 |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $22 | $A9 | Multiply by 0.0003 | No dimension | Oxygen storage capacity of catalyst - Bank 2 |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $3D | $C9 | Multiply by 0.001 | kPa | Test value for small leak (P0456) |
| $3D | $CA | Multiply by 0.001 | kPa | Test value for gross leak (P0455) |
| $3D | $CB | Multiply by 0.001 | kPa | Test value for leak detection pump OFF stuck (P2401) |
| $3D | $CD | Multiply by 0.001 | kPa | Test value for leak detection pump ON stuck (P2402) |
| $3D | $CE | Multiply by 0.001 | kPa | Test value for vent valve OFF stuck (P2420) |
| $3D | $CF | Multiply by 0.001 | kPa | Test value for vent valve ON stuck (P2419) |
| $3D | $D0 | Multiply by 0.001 | kPa | Test value for reference orifice low flow (P043E) |
| $3D | $D1 | Multiply by 0.001 | kPa | Test value for reference orifice high flow (P043F) |
| $3D | $D4 | Multiply by 0.001 | kPa | Test value for purge VSV close stuck (P0441) |
| $3D | $D5 | Multiply by 0.001 | kPa | Test value for purge VSV open stuck (P0441) |
| $3D | $D7 | Multiply by 0.001 | kPa | Test value for purge flow insufficient (P0441) |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $42 | $91 | Multiply by 0.001 | Ohm | Oxygen sensor heater resistance bank 1 sensor 2 |
| $46 | $91 | Multiply by 0.001 | Ohm | Oxygen sensor heater resistance bank 2 sensor 2 |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $71 | $E1 | Multiply by 0.01 | g/sec. | Test value for AIR insufficient |
| $71 | $E2 | Multiply by 0.01 | kPa | Test value for AIR pump ON stuck |
| $71 | $E3 | Multiply by 0.01 | kPa | Test value for AIR pump OFF stuck |
| $71 | $E4 | Multiply by 0.01 | kPa | Test value for AIR valve(s) ON stuck |
| $71 | $E5 | Multiply by 0.01 | kPa | Test value for AIR valve(s) OFF stuck |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $72 | $E1 | Multiply by 0.01 | g/sec. | Test value for AIR insufficient |
| $72 | $E2 | Multiply by 0.01 | kPa | Test value for AIR pump ON stuck |
| $72 | $E3 | Multiply by 0.01 | kPa | Test value for AIR pump OFF stuck |
| $72 | $E4 | Multiply by 0.01 | kPa | Test value for AIR valve(s) ON stuck |
| $72 | $E5 | Multiply by 0.01 | kPa | Test value for AIR valve(s) OFF stuck |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $A1 | $0B | Multiply by 1 | Time | Total EWMA misfire count of all cylinders in last ten driving cycles EWMA: Exponential Weighted Moving Average |
| $A1 | $0C | Multiply by 1 | Time |
|
| $A2 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 1 in last ten driving cycles |
| $A2 | $0C | Multiply by 1 | Time |
|
| $A3 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 2 in last ten driving cycles |
| $A3 | $0C | Multiply by 1 | Time |
|
| $A4 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 3 in last ten driving cycles |
| $A4 | $0C | Multiply by 1 | Time |
|
| $A5 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 4 in last ten driving cycles |
| $A5 | $0C | Multiply by 1 | Time |
|
| $A6 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 5 in last ten driving cycles |
| $A6 | $0C | Multiply by 1 | Time |
|
| $A7 | $0B | Multiply by 1 | Time | Total EWMA misfire count of cylinder 6 in last ten driving cycles |
| $A7 | $0C | Multiply by 1 | Time |
|