DTCs
| Monitoring Item
| Malfunction Detection Condition
| Trouble Area
| Detection Timing
| Detection Logic
|
P0455
| EVAP gross leak
| Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check. If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that EVAP system has large leak.
| - Fuel tank cap (loose)
- Leakage from EVAP line
(Canister - Fuel tank)
- Leakage from EVAP line
(Purge VSV - Canister)
- Canister pump module
- Leakage from fuel tank
- Leakage from canister
| While ignition switch off
| 2 trip
|
P0456
| EVAP small leak
| Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check. If stabilized pressure higher than second reference pressure, ECM determines that EVAP system has small leak.
| - Fuel tank cap (loose)
- Leakage from EVAP line
(Canister - Fuel tank)
- Leakage from EVAP line
(Purge VSV - Canister)
- Canister pump module
- Leakage from fuel tank
- Leakage from canister
| While ignition switch off
| 2 trip
|
Sequence
| Operation
| Description
| Duration
|
-
| ECM activation
| Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
| 10 seconds
|
B
| First reference pressure measurement
| In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
| 15 minutes*
|
D
| Purge VSV monitor
| Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normality.
| 10 seconds
|
E
| Second reference pressure measurement
| After second reference pressure measurement, leak check performed by comparing first and second reference pressure. If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
| 60 seconds
|
-
| Final check
| Atmospheric pressure measured and then monitoring result recorded by ECM.
| -
|