DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0102 | MAF meter voltage less than 0.2 V for 3 seconds (1 trip detection logic) |
|
| P0103 | MAF meter voltage more than 4.9 V for 3 seconds (1 trip detection logic) |
|
| Mass Air Flow Rate (g/sec.) | Malfunction |
| Approximately 0.0 |
|
| 160.0 or more | Open in E2G circuit |
| Related DTCs | P0102: MAF meter range check (Low voltage) P0103: MAF meter range check (High voltage) |
| Required Sensors/Components (Main) | MAF meter |
| Required Sensors/Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate: Engine speed less than 4000 rpm 2 driving cycles: Engine speed 4000 rpm or more |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| MAF meter voltage | Less than 0.2 V |
| MAF meter voltage | More than 4.9 V |
| MAF meter voltage | 0.4 V to 2.2 V |

| 1.READ VALUE USING TECHSTREAM (MASS AIR FLOW RATE) |
Connect the Techstream to the DLC3.
Start the engine.
Turn the Techstream ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / MAF.
Read the values displayed on the Techstream.
| Mass Air Flow Rate (g/sec.) | Proceed to |
| 0.0 | A |
| 160.0 or more | B |
| Between 1.0 and 160.0* | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the D7 MAF meter connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D7-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
|
| ||||
| OK | |
| 3.INSPECT MASS AIR FLOW METER |
![]() |
Remove the Mass Air Flow (MAF) meter (Click here).
Inspect the MAF meter.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (E2G) - 3 (VG) |
| Voltage fluctuates |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-3 (VG) - D74-74 (VG) | Always | Below 1 Ω |
| D7-2 (E2G) - D74-75 (E2G) | Always | Below 1 Ω |
| D7-3 (VG) or D74-74 (VG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
![]() |
Check the EFI NO. 2 fuse.
Remove the EFI NO. 2 fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| EFI NO. 2 fuse | Always | Below 1 Ω |
Reinstall the EFI NO. 2 fuse.
Disconnect the D7 MAF meter connector.
Remove the integration relay from the engine room relay block .
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-1 (+B) - 1B-4 | Always | Below 1 Ω |
| D7-1 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-3 (VG) - D74-74 (VG) | Always | Below 1 Ω |
| D7-2 (E2G) - D74-75 (E2G) | Always | Below 1 Ω |
| D7-3 (VG) or D74-74 (VG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
![]() |
Disconnect the D7 MAF meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-2 (E2G) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||