Home › TRANSMISSION · AB60E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0894    Transmission Component Slipping

DTC    P2714    Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION


C161167E01

The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The ECM adjusts the duty ratio* of the SLT solenoid valve to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

HINT:
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100


DTC Code
DTC Detection Condition
Trouble Area
P0894
The ECM detects a malfunction on SLT, S1, S2, S3, S4, SL2, gear 6 incorrect ratio (sequence valve) or 1-2 shift solenoid valve according to the revolution difference of the turbine and the output shaft, and also by the oil pressure. (2-trip detection logic)
  1. Shift solenoid valve SLT remains open or closed
  2. Shift solenoid valve S1, S2, S3, S4 or SL2 remains open or closed
  3. Gear 6 incorrect ratio (sequence valve) or 1-2 shift valve is stuck
  4. Valve body is blocked
  5. Automatic transmission (clutch, brake, gear, etc.)
P2714
The ECM detects a malfunction on SLT (ON side) according to the revolution difference of the turbine and the output shaft, and also by the oil pressure (2 trip detection logic)
  1. Shift solenoid valve SLT remains open or closed
  2. Shift solenoid valve S1, S2, S3, S4 or SL2 remains open or closed
  3. Gear 6 incorrect ratio (sequence valve) or 1-2 shift valve is stuck
  4. Valve body is blocked
  5. Automatic transmission (clutch, brake, gear, etc.)

MONITOR DESCRIPTION

The ECM calculates the amount of heat absorbed by the friction material based on the difference in revolution (clutch slippage) between the turbine and output shaft. The ECM illuminates the MIL and outputs these DTCs when the amount of heat absorption exceeds the specified value.
There are two causes of revolution difference.
  1. When the shift solenoid valve SLT remains ON, oil pressure decreases, which causes the clutch engagement force to decrease.
  2. When the shift solenoid valve remains ON or OFF, the gear position commanded by the ECM and the actual gear position are not the same.

NOTICE:
If you continue driving under these conditions, the clutch will burn out and the vehicle will no longer be drivable.


MONITOR STRATEGY


Related DTCs
P0894: Automatic transmission slip malfunction
P2714: Shift solenoid valve SLT/ON malfunction
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
P0894 ON malfunction (A): Immediately
P0894 ON malfunction (B): 0.4 seconds
P2714: Immediately
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever the following DTCs are not present
None
Turbine speed sensor circuit
Not circuit malfunction
Output speed sensor circuit
Not circuit malfunction
ATF temperature sensor circuit
Not circuit malfunction
Shift solenoid valve S1 circuit
Not circuit malfunction
Shift solenoid valve S2 circuit
Not circuit malfunction
Shift solenoid valve S3 circuit
Not circuit malfunction
Shift solenoid valve S4 circuit
Not circuit malfunction
Shift solenoid valve SR circuit
Not circuit malfunction
Shift solenoid valve SL1 circuit
Not circuit malfunction
Shift solenoid valve SL2 circuit
Not circuit malfunction
Shift solenoid valve SLT circuit
Not circuit malfunction
ECT (Engine coolant temperature) sensor circuit
Not circuit malfunction
KCS sensor circuit
Not circuit malfunction
ETCS (Electric Throttle Control System)
Not system down
Transmission position
"D"
Duration time from shifting "N" to "D"
4 seconds or more
ECT
40°C (104°F) or more
Spark advance from max. retard timing by KCS control
0° crankshaft angle or more
Engine
Starting

TYPICAL MALFUNCTION THRESHOLDS

[P0894: ON malfunction]
  1. When either condition below is met: ON malfunction (A) or (B)

ON Malfunction (A) 
Summation of C1 clutch heat generations
Specified value

ON Malfunction (B) 
Summation of C2 clutch heat generations
Specified value
Actual gear for SLT failure judgment
Not determined
[P2714: ON malfunction]
  1. One of the following conditions is met: ON malfunction (A), (B), (C), (D), (E), (F), (G) or (H)

ON Malfunction (A) 
Summation of C1 clutch heat generations
Specified value

ON Malfunction (B) 
Shift solenoid valve S1 OFF malfunction
Detected

ON Malfunction (C) 
Shift solenoid valve S2 OFF malfunction
Detected

ON Malfunction (D) 
Shift solenoid valve S3 ON malfunction
Detected

ON Malfunction (E) 
Shift solenoid valve S4 OFF malfunction
Detected

ON Malfunction (F) 
1-2 shift valve malfunction
Detected

ON Malfunction (G) 
Sequence valve malfunction
Detected

ON Malfunction (H) 
Shift solenoid valve SL2 ON malfunction
Detected

INSPECTION PROCEDURE

1.CHECK DTC OUTPUT (IN ADDITION TO DTCS P0894 AND P2714)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read the DTCs using the Techstream.
    Result 
    Result
    Proceed to
    1. Only P0894 is output
    2. Only P0894 and P2714 are output
    A
    P0894, P2714 and other DTCs are output
    B

    HINT:
    If any other codes besides P0894 and P2714 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.PERFORM ACTIVE TEST USING TECHSTREAM (SHIFT SOLENOID VALVE SLT)

NOTICE:
  1. Perform the test at the normal operating ATF temperature: 50 to 80°C (122 to 176°F).
  2. Be careful to prevent SST's hose from interfering with the exhaust pipe.
  3. Perform the test with the A/C OFF.

HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.



    C161166E01
  1. Remove the test plug on the transmission case center right side and connect SST.

SST
09992-00095   (09992-00231, 09992-00271)
  1. Connect the Techstream to the DLC3.

  1. Start the engine and warm it up.

  1. Measure the line pressure with SST.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test.

  1. According to the display on the Techstream, perform the Active Test.

  1. Measure the line pressure.

    Engine and ECT: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Activate the Solenoid (SLT)*
    Operate shift solenoid SLT and raise line pressure
    ON or OFF

    HINT:
    1. OFF: Line pressure up (when Active Test "Activate the Solenoid (SLT)" is performed, ECM commands SLT solenoid to turn OFF)
    2. ON: No action (normal operation)

    [Vehicle Condition]
    1. Vehicle stopped
    2. Engine idling

    HINT:
    *: Activate the Solenoid (SLT) in the Active Test is performed to check the line pressure changes by connecting SST to the automatic transmission, which is used in the Hydraulic Test (Click here) as well. Note that the pressure values in the Active Test and Hydraulic Test are different.

    OK:
    The line pressure changes as specified when performing the Active Test.



NG
Go to step 9
OK


3.PERFORM ACTIVE TEST USING TECHSTREAM (RUNNING TEST)

CAUTION:
This test should always be performed with at least 2 people.

NOTICE:
  1. Perform the test at the normal operating ATF temperature: 50 to 80°C (122 to 176°F).
  2. Perform the test with the A/C turned off.

  1. Connect the Techstream to the DLC3.

  1. Clear the DTC (Click here).

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test.

  1. According to the display on the Techstream, perform the Active Test.

    HINT:
    While driving, the shift position can be forcibly changed with the Techstream.


    Engine and ECT: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Control the Shift Position
    Operate shift solenoid valve and set each shift position
    1. Press "→" button: Shift up
    2. Press "←" button: Shift down
    Possible to check operation of shift solenoid valves
    [Vehicle Condition]
    50 km/h (31 mph) or less

    HINT:
    1. This test can be conducted when the vehicle speed is 50 km/h (31 mph) or less.
    2. The 4th to 5th and 5th to 6th up-shifts must be performed with the accelerator pedal released.
    3. The 6th to 5th and 5th to 4th down-shifts must be performed with the accelerator pedal released.
    4. Do not operate the accelerator pedal for at least 2 seconds after shifting and do not shift successively.
    5. The shift position commanded by the ECM is shown in the Data List display on the Techstream.

  1. Compare the ECM gear shift command and the actual gear position.

    OK:
    Gear position changes in accordance with the Techstream command.


    Result 
    System Condition
    ECM Gear Shift Command
    Proceed to
    1st
    2nd
    3rd
    4th
    5th
    6th
    Malfunction
    Shift solenoid S1
    Stuck ON*1
    2nd
    2nd
    3rd
    4th
    5th
    6th
    A
    Stuck OFF
    1st
    1st
    3rd
    4th
    5th
    N*2
    Shift solenoid S2
    Stuck ON
    1st
    2nd
    2nd
    4th
    6th
    6th
    B
    Stuck OFF
    3rd
    3rd
    3rd
    4th
    5th
    5th
    Shift solenoid S3
    Stuck ON
    1st
    2nd
    3rd
    3rd
    N*2
    N*2
    C
    Stuck OFF
    3rd
    4th
    4th
    4th
    5th
    6th
    Shift solenoid S4
    Stuck ON*3
    1st
    2nd
    3rd
    4th
    5th
    6th
    D
    Stuck OFF
    1st
    2nd
    3rd
    4th
    4th
    4th
    Normal
    1st
    2nd
    3rd
    4th
    5th
    6th
    E

    HINT:
    1. *1: When shift solenoid S1 is stuck ON, the vehicle cannot drive in reverse.
    2. *2: Neutral
    3. *3: When shift solenoid S4 is stuck ON, gear shifting is normal.



B
Go to step 5

C
Go to step 6

D
Go to step 7

E
Go to step 9
A


4.INSPECT SHIFT SOLENOID VALVE S1


    C160563E01
  1. Remove shift solenoid valve S1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 10
A

REPLACE SHIFT SOLENOID VALVE S1  

5.INSPECT SHIFT SOLENOID VALVE S2


    C160564E01
  1. Remove shift solenoid valve S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 10
A

REPLACE SHIFT SOLENOID VALVE S2  

6.INSPECT SHIFT SOLENOID VALVE S3


    C160563E02
  1. Remove shift solenoid valve S3.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 10
A

REPLACE SHIFT SOLENOID VALVE S3  

7.INSPECT SHIFT SOLENOID VALVE S4


    C123198E03
  1. Remove shift solenoid valve S4.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE S4
OK


8.INSPECT SHIFT SOLENOID VALVE SL2


    C151311E17
  1. Remove shift solenoid valve SL2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the battery's positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 10
A

REPLACE SHIFT SOLENOID VALVE SL2  

9.INSPECT SHIFT SOLENOID VALVE SLT


    C162477E01
  1. Remove shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes an operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK


10.INSPECT TRANSMISSION VALVE BODY ASSEMBLY
  1. Check the transmission valve body assembly (Click here).

    OK:
    There are no foreign objects on any valve.



NG
REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY (Click here)
OK


11.INSPECT TORQUE CONVERTER CLUTCH ASSEMBLY
  1. Check the torque converter clutch assembly (Click here).

    OK:
    The torque converter clutch operates normally.



NG
REPLACE TORQUE CONVERTER CLUTCH ASSEMBLY (Click here)
OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY (Click here)