Home › ENGINE · 3UR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0418    Secondary Air Injection System Control "A" Circuit

DTC    P0419    Secondary Air Injection System Control "B" Circuit

for Preparation Click here


DESCRIPTION

Refer to DTC P0412 .

DTC Code
DTC Detection Condition
Trouble Area
P0418
P0419
  1. After cold engine starts, all of following conditions met (1 trip detection logic):
    1. Secondary Air Injection (AIR) system not operating (air pump OFF, Air Switching Valve [ASV] OFF)
    2. Diagnostic signal from Air Injection Control Driver (AID) 20%
    3. Battery voltage 8 V or more
  1. Open in air pump drive circuit
  2. Air pump
  3. AID
  4. ECM
P0418
P0419
  1. After cold engine starts, all of following conditions met (1 trip detection logic):
    1. Secondary Air Injection (AIR) system operating (air pump ON, Air Switching Valve [ASV] ON)
    2. Diagnostic signal from Air Injection Control Driver (AID) 20%
    3. Battery voltage 8 V or more
  1. Short between air pump drive circuit and body ground
  2. Air pump
  3. AID
  4. ECM

MONITOR DESCRIPTION

The Air Injection Control Driver (AID) detects open and short circuits according to the voltages of the air pump terminal (VP) and the Air Switching Valve (ASV) terminal (VV), and transmits diagnostic information as a signal to the ECM.
For a short time after cold engine starts, the ECM transmits command signals to the AID to drive the air pump and ASV.
The AID transmits an air pump malfunction signal to the ECM if either of the following conditions is met:
  1. The voltage at the AID terminal relating to the air pump is low despite the AID receiving command signals from the ECM to drive the air pump.
  2. The voltage at the AID terminal relating to the air pump is high despite the AID receiving no command signals from the ECM to drive the air pump.
The ECM sets the DTC based on diagnostic signals from the AID.

MONITOR STRATEGY


Related DTCs
P0418: Secondary air injection system air pump circuit range check (Bank 1)
P0419: Secondary air injection system air pump circuit range check (Bank 2)
Required Sensors/Components (Main)
Air injection control driver
Required Sensors/Components (Related)
Air pump
Frequency of Operation
Once per drive cycle
Duration
3 seconds
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Case 1: 
Monitor runs whenever following DTCs not present
-
Secondary air injection pump
Operating
Secondary air injection switching valve
Operating
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

Case 2: 
Monitor runs whenever following DTCs not present
-
Secondary air injection pump
Not operating
Secondary air injection switching valve
Not operating
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Diagnostic signal duty ratio from air injection control driver
11% or more, and 29% or less

COMPONENT OPERATING RANGE


Diagnostic signal duty ratio from air injection control driver
70% or more, and 90% or less when secondary air injection system operating.
0% when secondary air injection system not operating.

WIRING DIAGRAM

Refer to DTC P0412 .

INSPECTION PROCEDURE

HINT:
Diagnostic information output by the AID can be confirmed by connecting an oscilloscope to the diagnostic information terminal of the AID. Reading the waveform while performing the AIR system intrusive operation provided in the System Check function allows the possible trouble areas to be narrowed down.

NOTICE:
  1. This Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds. Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks. While AIR system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
    If an ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
  2. Performing the Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
  3. When performing the Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
  4. Turn the ignition switch off when the Air Injection Check operation finishes.


AID Diagnostic Signal Waveforms
ECM
Commands
DTCs
(ECM Output)
Suspected Trouble Areas
100% Duty Ratio
A112066E01
Any Secondary Air Injection (AIR) System operation
P1613
P1614
  1. Open in diagnostic signal circuit
  2. Air Injection Control Driver (AID)
  3. Open in AID BATT circuit
  4. Short between +B and diagnostic signal circuits
0% Duty Ratio
A112067E01
AIR System: ON (Air pump ON, ASV ON)
P1613
P1614
  1. Open or short in air pump or Air Switching Valve (ASV) command signal circuit (ECM-AID)
  2. Short between diagnostic signal circuit and body ground
  3. AID
  4. ECM
AIR System: OFF (Air pump OFF, ASV OFF)
-
Normal
20% Duty Ratio
A112068E01
Air Pump: ON
P0418
P0419
  1. Short between air pump drive circuit and body ground
  2. Harness and connector (AID-Pump)
  3. Air pump
  4. AID
  5. ECM
Air Pump: OFF
P0418
P0419
  1. Open in air pump drive circuit (AID-Pump)
  2. Harness and connector (AID-Pump)
  3. Air pump
  4. AID
  5. ECM
40% Duty Ratio
A112069E01
ASV: ON
P0412
P0415
  1. Short between ASV drive circuit and body ground
  2. Harness and connector (AID-ASV)
  3. ASV
  4. AID
  5. ECM
ASV: OFF
P0412
P0415
  1. Open in ASV drive circuit (AID-ASV)
  2. Harness and connector (AID-ASV)
  3. AID
  4. ASV
  5. ECM
80% Duty Ratio
A112070E01
AIR System: OFF (Air pump OFF, ASV OFF)
P1613
P1614
  1. AID
  2. ECM
AIR System: ON (Air pump ON, ASV ON)
-
Normal
Other than above
(other than 0, 20, 40, 80 and 100% duty)
-
P1613
P1614
  1. AID
  2. Open in AID ground circuit

HINT:
  1. By using the Techstream to perform the Air Injection Check operation in the System Check, the air-fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.INSPECT AIR PUMP ASSEMBLY
A160904E03
  1. Disconnect the D56 or D57 air pump connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    0.44 to 1 Ω



NG
REPLACE AIR PUMP ASSEMBLY (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (AIR PUMP - BODY GROUND)
A160905E11
  1. Disconnect the D56 or D57 air pump connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D56-1 - Body ground
    Always
    Below 1 Ω
    D57-1 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (AIR PUMP - AIR INJECTION CONTROL DRIVER)
A162280E04
  1. Disconnect the D56 or D57 air pump connector.

  1. Disconnect the D48 or D52 AID connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D56-2 - D48-2 (VP)
    Always
    Below 1 Ω
    D57-2 - D52-2 (VP2)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR INJECTION CONTROL DRIVER (Click here)