DTC P0451 Evaporative Emission Control System Pressure Sensor Range / Performance |
DTC P0452 Evaporative Emission Control System Pressure Sensor / Switch Low Input |
DTC P0453 Evaporative Emission Control System Pressure Sensor / Switch High Input |
| DTC Code | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0451 | Canister pressure sensor noise | Sensor output voltage fluctuates frequently within certain time period. |
|
| 2 trip |
| Canister pressure sensor signal becomes fixed/flat | Sensor output voltage does not vary within certain time period. |
|
| 2 trip | |
| P0452 | Canister pressure sensor low input | EVAP pressure less than 42.1 kPa for 0.5 seconds. |
|
| 1 trip |
| P0453 | Canister pressure sensor high input | EVAP pressure more than 123.8 kPa for 0.5 seconds. |
|
| 1 trip |

| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Once per driving cycle: P0451 sensor fixed/flat Continuous: P0451 sensor noise, P0452 and P0453 |
| Duration | 0.5 seconds: P0452 and P0453 2 minutes: P0451 |
| MIL Operation | Immediate: P0452 and P0453 2 driving cycles: P0451 |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | P0452, 0453 (EVAP System) |
| Atmospheric pressure (absolute pressure) | 70 to 110 kPa-a (525 to 825 mmHg-a) |
| Battery voltage | 10.5 V or more |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| Either of following conditions met | A or B |
| A. Engine condition | Running |
| B. Time after key off | 5 or 7 or 9.5 hours |
| Monitor runs whenever following DTCs not present | P0452, 0453 (EVAP System) |
| Battery voltage | 10.5 V or more |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| Atmospheric pressure (absolute pressure) | Less than 70 kPa-a (525 mmHg-a) or 110 kPa-a (825 mmHg-a) or more |
| Time after key off | 5 or 7 or 9.5 hours |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 8 V or more |
| Starter | OFF |
| Either of following conditions met | (a) or (b) |
| (a) Ignition switch | ON |
| (b) Soak timer | ON |
| Frequency that EVAP pressure change 0.3 kPa-g (2.25 mmHg-g) or more | 10 times or more in 10 seconds |
| EVAP pressure change during reference pressure | Less than 0.65 kPa-g (4.87 mmHg-g) |
| EVAP pressure | Less than 42.1 kPa-a (315.9 mmHg-a) |
| EVAP pressure | More than 123.8 kPa-a (928.4 mmHg-a) |

| 1.CONFIRM DTC AND EVAP PRESSURE |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (do not start the engine).
Turn the Techstream ON.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
Enter the following menus: Powertrain / Engine and ECT / Data List / EVAP / Vapor Pressure Pump.
Read the EVAP (Evaporative Emission) pressure displayed on the Techstream.
| Display (DTC Output) | Test Result | Suspected Trouble Area | Proceed to |
| P0451 | - | Canister pressure sensor | C |
| P0452 | Less than 45 kPa-a (430 mmHg-a) |
| A |
| P0453 | More than 120 kPa-a (900 mmHg-a) |
| B |
|
| ||||
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
![]() |
Turn the ignition switch off.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Suspected Trouble Area | Proceed to |
| D74-121 (PPMP) - Body ground | Always | 10 Ω or less |
| A |
| D74-121 (PPMP) - Body ground | Always | 10 kΩ or more |
| B |
|
| ||||
| A | |
| 3.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
![]() |
Disconnect the R1 canister pump module connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Suspected Trouble Area | Proceed to |
| D74-121 (PPMP) - Body ground | Always | 10 kΩ or more | Short in canister pressure sensor circuit | A |
| D74-121 (PPMP) - Body ground | Always | 10 Ω or less | Short in wire harness/connector (ECM - Canister pressure sensor) | B |
|
| ||||
|
| ||||
| 4.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
![]() |
Disconnect the R1 canister pump module connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| R1-2 (SGND) - Body ground | Always | 100 Ω or less |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| R1-4 (VCC) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
| R1-3 (VOUT) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
| Test Result | Suspected Trouble Area | Proceed to |
| Voltage and resistance within standard ranges | Open in canister pressure sensor circuit | A |
| Voltage and resistance outside standard ranges | Open in wire harness/connector (ECM - Canister pressure sensor) | B |
|
| ||||
| A | |
| 5.REPLACE CHARCOAL CANISTER ASSEMBLY |
Replace the canister assembly (Click here).

|
| ||||
| 6.REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
| ||||
| 7.REPLACE ECM |
Replace the ECM (Click here).
| NEXT | |
| 8.CHECK WHETHER DTC OUTPUT RECURS (AFTER REPAIR) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream ON.
Wait for at least 60 seconds.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes / Pending.
| NEXT | ||
| ||