COMPRESSOR AND MAGNETIC CLUTCH (for 1GR-FE) > REMOVAL |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start up the engine.
Turn the A/C switch ON.
Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the compressor oil remaining in each component into the cooler compressor.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. REMOVE FENDER APRON MUDGUARD SEAL LH |
![]() |
Remove the 6 clips and seal.
| 3. REMOVE FAN AND GENERATOR V BELT |
![]() |
While releasing the belt tension by turning the belt tensioner counterclockwise, remove the fan and generator V belt from the belt tensioner.
| 4. DISCONNECT DISCHARGE HOSE |
![]() |
Remove the bolt and disconnect the cooler refrigerant discharge hose from the cooler compressor.
Remove the O-ring from the cooler refrigerant discharge hose.
| 5. DISCONNECT SUCTION HOSE |
![]() |
Remove the bolt and disconnect the cooler refrigerant suction hose from the cooler compressor.
Remove the O-ring from the cooler refrigerant suction hose.
| 6. REMOVE COOLER COMPRESSOR ASSEMBLY |
![]() |
Disconnect the connector.
Remove the 2 bolts and 2 nuts.
Remove the 2 stud bolts and cooler compressor.