GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR ROTOR ASSEMBLY |
![]() |
Check the rotor for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Slip ring | 20°C (68°F) | 2.3 to 2.7 Ω |
| Tester Connection | Condition | Specified Condition |
| Slip ring - Slip ring | 20°C (68°F) | 1.5 to 1.9 Ω |
![]() |
Check if the rotor is grounded.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Slip ring - Rotor | Always | 10 kΩ or higher |
Check that the slip rings are not rough or scored.
If rough or scored, replace the rotor assembly.
![]() |
Using a vernier caliper, measure the slip ring diameter.
| 2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
![]() |
Using a vernier caliper, measure the exposed brush length.
| 3. INSPECT GENERATOR DRIVE END FRAME BEARING |
![]() |
When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
If necessary, replace the bearing.
| 4. REPLACE GENERATOR DRIVE END FRAME BEARING |
![]() |
Remove the 4 screws and retainer plate.
![]() |
Using SST and a hammer, tap out the bearing.
![]() |
Using SST and a press, press in a new bearing.
![]() |
Install the retainer plate with the 4 screws.
| 5. INSPECT GENERATOR ROTOR BEARING |
![]() |
When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
If necessary, replace the generator rotor.