Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › SOLAR SENSOR (for Automatic Air Conditioning System)

SOLAR SENSOR (for Automatic Air Conditioning System) > INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (SOLAR SENSOR)


B109993E33
  1. Connect the battery's positive (+) lead to terminal 6 and the negative (-) lead to terminal 3, then measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    1 (TSL) - 3 (CLTE)
    Sensor subject to electric light
    0.8 to 4.3 V
    Sensor covered with a cloth
    0.8 V or less
    2 (TSR) - 3 (CLTE)
    Sensor subject to electric light
    0.8 to 4.3 V
    Sensor covered with a cloth
    0.8 V or less

    NOTICE:
    The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above.

    HINT:
    1. As the inspection light is moved away from the sensor, the voltage decreases.
    2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the solar sensor.

    If the result is not as specified, replace the solar sensor.