Home › ENGINE ยท 2UZ-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P043E    Evaporative Emission System Leak Detection Reference Orifice Low Flow

DTC    P043F    Evaporative Emission System Reference Orifice High Flow

DTC    P2401    Evaporative Emission Leak Detection Pump Stuck OFF

DTC    P2402    Evaporative Emission Leak Detection Pump Stuck ON

DTC    P2419    Evaporative Emission System Switching Valve Control Circuit Low

for Preparation Click here


DTC SUMMARY


DTC
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P043E
Reference orifice clogged
P043E, P043F, P2401, P2402 and P2419 present when one of following conditions met during key-off EVAP monitor:
  1. Reference orifice clogged
  2. Reference orifice high-flow
  3. Leak detection pump OFF malfunction
  4. Leak detection pump ON malfunction
  5. Vent valve ON (close) malfunction
  1. Canister pump module (Reference orifice, leak detection pump, vent valve)
  2. Connector/wire harness (Canister pump module - ECM)
  3. EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
  4. ECM
While ignition switch off
2 trip
P043F
Reference orifice high-flow
P2401
Leak detection pump stuck OFF
P2402
Leak detection pump stuck ON
P2419
Vent valve stuck closed

HINT:
The reference orifice is located inside the canister pump module.


DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to the EVAP System .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence
Operation
Description
Duration
-
ECM activation
Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
10 seconds
B
First reference pressure measurement
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E
Second reference pressure measurement
After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
-
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E14

The leak detection pump creates negative pressure through the reference orifice. When the system is normal, the EVAP pressure is between 724 to 752 mmHg* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM will illuminate the MIL and set DTC if this malfunction is detected in consecutive drive cycles.
*: Typical value.

A137887E04


MONITOR STRATEGY


Required Sensors/Components
Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 2 minutes
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
P0451, P0452, P0453 (EVAP System)
EVAP key-off monitor runs when all of following conditions met
-
Atmospheric pressure
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or higher
Vehicle speed
Below 4 km/h (2.5 mph)
Ignition switch
Off
Time after key off
5 or 7 or 9.5 hours
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before key off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
ECT
4.4 to 35°C (40 to 95°F)
IAT
4.4 to 35°C (40 to 95°F)

TYPICAL MALFUNCTION THRESHOLDS

"Saturated" indicates that the EVAP pressure change is less than 0.286 kPa-g (2.14 mmHg-g) in 60 seconds.

One of following conditions met
-
EVAP pressure just after reference pressure measurement started
More than -1 kPa-g (-7.5 mmHg-g)
Reference pressure
Less than -4.85 kPa-g (-36.4 mmHg-g)
Reference pressure
-1.057 kPa-g (-7.93 mmHg-g) or more
Reference pressure
Not saturated within 60 seconds
Reference pressure difference between first and second
0.7 kPa-g (5.25 mmHg-g) or more

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).